Lessons learned and ongoing research at Electra: a rep-rate excimer laser facility

Electra is a repetitively pulsed, electron beam pumped excimer laser at the Naval Research Laboratory where we are developing the technologies that can meet the Inertial Fusion Energy (IFE) requirements for durability, efficiency, and cost. The technologies developed on Electra are designed to be directly scalable to a fusion power plant beam line. As in a full-size fusion power plant beam line, Electra has been utilized as the ultimate amplifier in a laser amplifier system. The 500 keV doubled sided electron beam pumped (100 ns flat-top) main amplifier in krypton fluoride (KrF) oscillator mode has demonstrated single shot and rep-rate laser energies exceeding 700 J with 100 ns pulse width at 248 nm with an aperture 29 x 29 cm<sup>2</sup>. Continuous operation of the KrF electron beam pumped oscillator has lasted for more than 2.5 hours without failure at 1 Hz and 10 hours without failure at 2.5 Hz. The measured intensity and pulse energy for durations greater than thousand shots are consistent at measurable rep-rates of 1 Hz, and 2.5 Hz. The laser oscillator also demonstrated 50,000 shots on the same foils at 5 Hz operation. Recently, the electron beam diodes of the Electra facility have been modified to a reduced aperture to increase the power deposition rate for efficient argon fluoride at 193 nm operations. In addition, new electron beam window materials and configurations have been investigated to enhance ArF yield. The Electra facility achieved 200 Joules at 193 nm with single shot performance with a reduced (relative to KrF) lasing beam size of 10 x 29 cm<sup>2</sup>. Gain measurements at 193 nm indicate higher wall-plug efficiency for ArF (10%) than KrF (7%). The native emission of argon fluoride bandwidth exceeds 10 THz which is broader than the krypton fluoride bandwidth of a few THz.

Authors

Institutions

Publication Details

Published
2025-03-19
DOI
https://doi.org/10.1117/12.3041918
Citations
1
Primary Topic
Laser Design and Applications
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lessons learned and ongoing research at Electra: a rep-rate excimer laser facility

M. C. Myers, M. F. Wolford
1 citations
Laser Design and Applications
0.73
article

Lessons learned and ongoing research at Electra: a rep-rate excimer laser facility

M. C. Myers, M. F. Wolford
article en
1 citations

Abstract

Electra is a repetitively pulsed, electron beam pumped excimer laser at the Naval Research Laboratory where we are developing the technologies that can meet the Inertial Fusion Energy (IFE) requirements for durability, efficiency, and cost. The technologies developed on Electra are designed to be directly scalable to a fusion power plant beam line. As in a full-size fusion power plant beam line, Electra has been utilized as the ultimate amplifier in a laser amplifier system. The 500 keV doubled sided electron beam pumped (100 ns flat-top) main amplifier in krypton fluoride (KrF) oscillator mode has demonstrated single shot and rep-rate laser energies exceeding 700 J with 100 ns pulse width at 248 nm with an aperture 29 x 29 cm<sup>2</sup>. Continuous operation of the KrF electron beam pumped oscillator has lasted for more than 2.5 hours without failure at 1 Hz and 10 hours without failure at 2.5 Hz. The measured intensity and pulse energy for durations greater than thousand shots are consistent at measurable rep-rates of 1 Hz, and 2.5 Hz. The laser oscillator also demonstrated 50,000 shots on the same foils at 5 Hz operation. Recently, the electron beam diodes of the Electra facility have been modified to a reduced aperture to increase the power deposition rate for efficient argon fluoride at 193 nm operations. In addition, new electron beam window materials and configurations have been investigated to enhance ArF yield. The Electra facility achieved 200 Joules at 193 nm with single shot performance with a reduced (relative to KrF) lasing beam size of 10 x 29 cm<sup>2</sup>. Gain measurements at 193 nm indicate higher wall-plug efficiency for ArF (10%) than KrF (7%). The native emission of argon fluoride bandwidth exceeds 10 THz which is broader than the krypton fluoride bandwidth of a few THz.

United States Naval Research Laboratory (US)
Openalex Percentile: Top 30%
Laser Design and Applications
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.