Optimizing CRT Lead Placement Accuracy With CMR-Guided On-Screen Targeting
Image-guided implantation resulted in significantly more LVPE placed in the target area and greater LVESV reduction in patients with myocardial scar.
Authors
- Alexander H. Maass (ORCID: https://orcid.org/0000-0002-7936-360X)
- Pim van der Harst (ORCID: https://orcid.org/0000-0002-2713-686X)
- Marco Guglielmo (ORCID: https://orcid.org/0000-0003-1718-9949)
- Antonius van Stipdonk (ORCID: https://orcid.org/0000-0002-6621-0727)
- Philippe Wouters (ORCID: https://orcid.org/0000-0002-3406-4083)
- Vokko P. van Halm
- Sing‐Chien Yap (ORCID: https://orcid.org/0000-0003-4520-2725)
- Maarten J. Cramer
- Frebus J. van Slochteren
- Mathias Meine (ORCID: https://orcid.org/0000-0002-1102-2155)
- Kevin Vernooy (ORCID: https://orcid.org/0000-0002-8818-5964)
- Willem Gerrits
- Vincent F. van Dijk (ORCID: https://orcid.org/0000-0002-3832-1518)
- Cheyenne S L Chiu (ORCID: https://orcid.org/0000-0002-2121-3713)
- Abdul Ghani
Institutions
- University Medical Center Groningen (NL)
- Utrecht University (NL)
- Erasmus MC (NL)
- University Medical Center Utrecht (NL)
- Maastricht University (NL)
- St. Antonius Ziekenhuis (NL)
- Haga Hospital (NL)
- Isala (NL)
- Amsterdam University Medical Centers (NL)
Publication Details
- Journal
- JACC. Clinical electrophysiology
- Published
- 2025-03-19
- DOI
- https://doi.org/10.1016/j.jacep.2025.01.022
- Citations
- 4
- Primary Topic
- Cardiac pacing and defibrillation studies
- Type
- article
- Field-Weighted Citation Impact
- 5.55
Funders
- ZonMw