Resin-embedded ex vivo mouse retina as durable phantoms for optical coherence tomography

Reliable performance testing, calibration, and comparative benchmarking of high-resolution optical coherence tomography (HR-OCT) systems requires durable and standardized phantoms with optical tissue properties. Here, we tested different sample preparation procedures combining various fixative mixtures, infiltration protocols and embedding resins for the establishment of durable retina phantoms. Sample quality was analyzed by evaluation of retina cell layers and tissue defects in volume scans acquired with a commercial HR-OCT system. Our results demonstrate that, by following appropriate preparation protocols, highly stable three-dimensional samples with layered structures as native healthy tissue can be fabricated. Even thin anatomic structures such as the ganglion single cell layer are preserved, which makes the new durable tissue phantoms highly suitable for reliable HR-OCT performance characterization.

Authors

Institutions

Publication Details

Published
2025-03-19
DOI
https://doi.org/10.1117/12.3043775
Primary Topic
Retinal Development and Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resin-embedded ex vivo mouse retina as durable phantoms for optical coherence tomography

Björn Kemper, Fernando García-Torres, Álvaro Barroso, Valery Naranjo et al.
Retinal Development and Disorders
article

Resin-embedded ex vivo mouse retina as durable phantoms for optical coherence tomography

Björn Kemper, Fernando García-Torres, Álvaro Barroso, Valery Naranjo, Jürgen Schnekenburger, Steffi Ketelhut, Peter Heiduschka, Rocío del Amor, Sandra Morales-Martínez
article en

Abstract

Reliable performance testing, calibration, and comparative benchmarking of high-resolution optical coherence tomography (HR-OCT) systems requires durable and standardized phantoms with optical tissue properties. Here, we tested different sample preparation procedures combining various fixative mixtures, infiltration protocols and embedding resins for the establishment of durable retina phantoms. Sample quality was analyzed by evaluation of retina cell layers and tissue defects in volume scans acquired with a commercial HR-OCT system. Our results demonstrate that, by following appropriate preparation protocols, highly stable three-dimensional samples with layered structures as native healthy tissue can be fabricated. Even thin anatomic structures such as the ganglion single cell layer are preserved, which makes the new durable tissue phantoms highly suitable for reliable HR-OCT performance characterization.

University of Münster (DE), Universitat Politècnica de València (ES)
Openalex Percentile: Top 95%
Retinal Development and Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.