Silicon slot waveguide for detection of methane with 300 ppb detection limit

Methane concentrations often exceed the atmospheric background level of approximately 2ppm across diverse industrial sites and landfills. Accurately registering subtle deviations from this atmospheric baseline, however, proves to be notoriously challenging, especially with chip-sized devices. Laser absorption spectroscopy with Photonic Integrated Circuits (PICs) is emerging as a breakthrough in addressing this challenge. We have been developing optical waveguides for MIR and, recently, we designed and fabricated a silicon slot waveguide for operation at 3270.4 nm, which coincides with a strong absorption peak of methane. The design was optimized for (i) a high air confinement, (ii) low lateral and substrate leakage, and (iii) single-mode operation at the target wavelength. Our slot waveguide employed for methane detection demonstrates a 1-σ detection limit (LOD) as low as 300ppb. This is one to two orders of magnitude lower than the current state-of-the-art, and the first instance where an on-chip device shows the capability to register methane changes below atmospheric background levels. Furthermore, in our effort to make the sensor more applicable in practical settings, we acknowledge and address operational constraints, particularly focusing on the impact of atmospheric humidity on the sensor performance. We studied the impact by exposing the waveguide to 70–75% relative humidity, which yielded a total propagation loss of 13.8 ± 0.4 dB cm<sup>–1</sup>. Baking the waveguide at 115 ± 5 °C for 10 min and then keeping it in dry N2 atmosphere reduced the loss to the 8.3 ± 0.3 dB cm<sup>–1</sup>. Removing the water is thus a major concern and may require e.g., a hydrophobic coating to stabilize the loss in the future.

Authors

Institutions

Publication Details

Published
2025-03-19
DOI
https://doi.org/10.1117/12.3062034
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Silicon slot waveguide for detection of methane with 300 ppb detection limit

Anurup Datta, Henock D. Yallew, Sebastián Alberti, Roman Zakoldaev et al.
Spectroscopy and Laser Applications
article

Silicon slot waveguide for detection of methane with 300 ppb detection limit

Anurup Datta, Henock D. Yallew, Sebastián Alberti, Roman Zakoldaev, Marek Vlk, Jana Jágerská
article en

Abstract

Methane concentrations often exceed the atmospheric background level of approximately 2ppm across diverse industrial sites and landfills. Accurately registering subtle deviations from this atmospheric baseline, however, proves to be notoriously challenging, especially with chip-sized devices. Laser absorption spectroscopy with Photonic Integrated Circuits (PICs) is emerging as a breakthrough in addressing this challenge. We have been developing optical waveguides for MIR and, recently, we designed and fabricated a silicon slot waveguide for operation at 3270.4 nm, which coincides with a strong absorption peak of methane. The design was optimized for (i) a high air confinement, (ii) low lateral and substrate leakage, and (iii) single-mode operation at the target wavelength. Our slot waveguide employed for methane detection demonstrates a 1-σ detection limit (LOD) as low as 300ppb. This is one to two orders of magnitude lower than the current state-of-the-art, and the first instance where an on-chip device shows the capability to register methane changes below atmospheric background levels. Furthermore, in our effort to make the sensor more applicable in practical settings, we acknowledge and address operational constraints, particularly focusing on the impact of atmospheric humidity on the sensor performance. We studied the impact by exposing the waveguide to 70–75% relative humidity, which yielded a total propagation loss of 13.8 ± 0.4 dB cm<sup>–1</sup>. Baking the waveguide at 115 ± 5 °C for 10 min and then keeping it in dry N2 atmosphere reduced the loss to the 8.3 ± 0.3 dB cm<sup>–1</sup>. Removing the water is thus a major concern and may require e.g., a hydrophobic coating to stabilize the loss in the future.

Centre for Arctic Gas Hydrate, Environment and Climate (NO), UiT The Arctic University of Norway (NO), Stanford University (US)
Affordable and clean energy
Openalex Percentile: Top 95%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.