Pellicle membrane for spectroscopic ellipsometry of viscous samples

Spectroscopic ellipsometry is a common non-destructive technique used to measure the thickness of thin films as well as their optical refractive index (n(λ)) and absorption coefficient (k(λ)). This technique relies on collecting a specular reflection from the surface of a sample over a range of wavelengths while measuring the polarization of the reflected light. Spectroscopic ellipsometry is predominantly used for non-viscous samples since measurements on viscous samples, such as liquids, are limited due to variations that cause inhomogeneity in the surface. Previous techniques have focused on measuring the optical parameters at the boundaries of liquids and solid materials or air. A light guide is used to propagate the light through a channel to the proximity of this liquid/material or air boundary. For ellipsometers with horizontal stages this is common practice, but many ellipsometers have vertical stages making it extremely difficult to use this method. In this presentation we describe a pellicle membrane that has made it possible to perform spectroscopic ellipsometry on liquid samples. As an example, we present results of measurements on distilled water allowing for accurate d

Authors

Institutions

Publication Details

Published
2025-03-19
DOI
https://doi.org/10.1117/12.3044757
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pellicle membrane for spectroscopic ellipsometry of viscous samples

Jesse A. Frantz, Cobey L. McGinnis, Jasbinder S. Sanghera, Jason D. Myers
2 links
Spectroscopy and Chemometric Analyses
article

Pellicle membrane for spectroscopic ellipsometry of viscous samples

Jesse A. Frantz, Cobey L. McGinnis, Jasbinder S. Sanghera, Jason D. Myers
article en

Abstract

Spectroscopic ellipsometry is a common non-destructive technique used to measure the thickness of thin films as well as their optical refractive index (n(λ)) and absorption coefficient (k(λ)). This technique relies on collecting a specular reflection from the surface of a sample over a range of wavelengths while measuring the polarization of the reflected light. Spectroscopic ellipsometry is predominantly used for non-viscous samples since measurements on viscous samples, such as liquids, are limited due to variations that cause inhomogeneity in the surface. Previous techniques have focused on measuring the optical parameters at the boundaries of liquids and solid materials or air. A light guide is used to propagate the light through a channel to the proximity of this liquid/material or air boundary. For ellipsometers with horizontal stages this is common practice, but many ellipsometers have vertical stages making it extremely difficult to use this method. In this presentation we describe a pellicle membrane that has made it possible to perform spectroscopic ellipsometry on liquid samples. As an example, we present results of measurements on distilled water allowing for accurate d

United States Naval Research Laboratory (US)
Openalex Percentile: Top 94%
Spectroscopy and Chemometric Analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.