Numerical analysis for laser endoluminal treatment of stress urinary incontinence

Stress urinary incontinence (SUI) is a sudden urine-leaking condition during physical activities due to weakened pelvic floor muscles or sphincter malfunction. Recently, a balloon-integrated diffusing applicator (DA) with 980 nm laser wavelength at 20W showed promising results for SUI treatment in light of urethral sphincter tightening and regeneration [1]. However, a large divergence beam emitted from DA can surpass a short treatment length of the sphincter (~16 mm) causing injury to the surrounding healthy tissue. A radial fiber (RF) emits a narrow beam width circumferentially around the fiber tip [2]. The current study aims to numerically compare the laser emission profiles from various angle fiber tips (β) in the balloon-integrated RF for SUI treatment. ZEMAX software was utilized for the numerical simulation. 0.22 NA 400-μm core diameter fibers with three β values were chosen for the simulation (i.e., β = 74°, 58°, and 42°) [2]. 980 nm laser at 20W was delivered by RFs. No significant difference was found among the output beam widths from RFs at the balloon surface (approximately 2 mm). The divergence angles (α) of the output beam from the tips decreased (α = 88°, 59°, and 33°) as β values decreased (β = 74°, 58°, and 42°), respectively. The starting position of the laser beam relative to the fiber tip (d) at the balloon surface was affected by the α values (i.e., d = 0, 1, and 2 mm for α = 88°, 59°, and 33°, respectively). According to the longitudinal emission, the normalized intensity peak for β = 74° was higher than those for β = 58° and 42° (i.e., 10% and 17%, respectively). Therefore, RF with β = 74° can control the position of the laser output beam more accurately and provide more effective energy than the other β values for the laser endoluminal treatment of SUI. Further studies will investigate the performance of RF with β = 74° in both ex vivo and in vivo models in terms of temperature distribution and wound healing.

Authors

Institutions

Publication Details

Published
2025-03-19
DOI
https://doi.org/10.1117/12.3041489
Primary Topic
Pelvic floor disorders treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical analysis for laser endoluminal treatment of stress urinary incontinence

Su Woong Jung, Hwarang Shin, Hyun Wook Kang, Jiho Lee et al.
Pelvic floor disorders treatments
article

Numerical analysis for laser endoluminal treatment of stress urinary incontinence

Su Woong Jung, Hwarang Shin, Hyun Wook Kang, Jiho Lee, Minh Duc Ta
article en

Abstract

Stress urinary incontinence (SUI) is a sudden urine-leaking condition during physical activities due to weakened pelvic floor muscles or sphincter malfunction. Recently, a balloon-integrated diffusing applicator (DA) with 980 nm laser wavelength at 20W showed promising results for SUI treatment in light of urethral sphincter tightening and regeneration [1]. However, a large divergence beam emitted from DA can surpass a short treatment length of the sphincter (~16 mm) causing injury to the surrounding healthy tissue. A radial fiber (RF) emits a narrow beam width circumferentially around the fiber tip [2]. The current study aims to numerically compare the laser emission profiles from various angle fiber tips (β) in the balloon-integrated RF for SUI treatment. ZEMAX software was utilized for the numerical simulation. 0.22 NA 400-μm core diameter fibers with three β values were chosen for the simulation (i.e., β = 74°, 58°, and 42°) [2]. 980 nm laser at 20W was delivered by RFs. No significant difference was found among the output beam widths from RFs at the balloon surface (approximately 2 mm). The divergence angles (α) of the output beam from the tips decreased (α = 88°, 59°, and 33°) as β values decreased (β = 74°, 58°, and 42°), respectively. The starting position of the laser beam relative to the fiber tip (d) at the balloon surface was affected by the α values (i.e., d = 0, 1, and 2 mm for α = 88°, 59°, and 33°, respectively). According to the longitudinal emission, the normalized intensity peak for β = 74° was higher than those for β = 58° and 42° (i.e., 10% and 17%, respectively). Therefore, RF with β = 74° can control the position of the laser output beam more accurately and provide more effective energy than the other β values for the laser endoluminal treatment of SUI. Further studies will investigate the performance of RF with β = 74° in both ex vivo and in vivo models in terms of temperature distribution and wound healing.

Pukyong National University (KR)
Zero hunger
Openalex Percentile: Top 92%
Pelvic floor disorders treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.