Assessment of generic corrections for multiview Cherenkov emission during total skin electron therapy (TSET)

Cherenkov imaging is a valuable tool for quality assurance of dose homogeneity in total skin electron therapy (TSET), where patients are treated in six postures using the Stanford technique. Cherenkov signals emitted from the patient's surface are captured, corrected, converted into 2D dose maps, and projected onto the body to generate a 3D pseudo dose distribution. This study aims to improve the accuracy of Cherenkov-converted doses by applying patient-specific generic correction factors derived from Monte Carlo simulations using finite element meshes (FEMs) reconstructed from 3D scans. A clinical study involving eight patients compared the corrected Cherenkov dose with in-vivo dosimetry (IVD) measurements. After applying generic corrections, the Cherenkov-converted dose showed good agreement with IVD, particularly in the shins, with discrepancies within 10%.

Authors

Institutions

Publication Details

Published
2025-03-19
DOI
https://doi.org/10.1117/12.3046423
Primary Topic
Cutaneous lymphoproliferative disorders research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of generic corrections for multiview Cherenkov emission during total skin electron therapy (TSET)

Brook K. Byrd, Lisha Chen, Timothy C. Zhu, Michael J. LaRiviere et al.
Cutaneous lymphoproliferative disorders research
article

Assessment of generic corrections for multiview Cherenkov emission during total skin electron therapy (TSET)

Brook K. Byrd, Lisha Chen, Timothy C. Zhu, Michael J. LaRiviere, Baozhu Lu, Brian W. Pogue, John P. Plastaras, Yifeng Zhu, Emily Xiong
article en

Abstract

Cherenkov imaging is a valuable tool for quality assurance of dose homogeneity in total skin electron therapy (TSET), where patients are treated in six postures using the Stanford technique. Cherenkov signals emitted from the patient's surface are captured, corrected, converted into 2D dose maps, and projected onto the body to generate a 3D pseudo dose distribution. This study aims to improve the accuracy of Cherenkov-converted doses by applying patient-specific generic correction factors derived from Monte Carlo simulations using finite element meshes (FEMs) reconstructed from 3D scans. A clinical study involving eight patients compared the corrected Cherenkov dose with in-vivo dosimetry (IVD) measurements. After applying generic corrections, the Cherenkov-converted dose showed good agreement with IVD, particularly in the shins, with discrepancies within 10%.

Vol. 13299
University of Wisconsin–Madison (US), University of Pennsylvania (US)
Dartmouth College, Tobacco Settlement Endowment Trust, National Institutes of Health
Openalex Percentile: Top 89%
Cutaneous lymphoproliferative disorders research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.