Axial-vapor-flow induced, low-liquid-saturation heat-pipe effect in wet insulation: Simulation and experiment

In field applications, segmented pipe thermal insulation wrappings are susceptible to inter-segment water penetration and its axial transport, which degrades the insulation thermal performance and causes pipe corrosion under insulation (CUI). Through CFD simulation , this axial transport, its local condensation/evaporation and liquid/vapor movement, and the temperature and liquid saturation distributions are predicted. The accompanying experiment (mineral wool insulation) conditions are a horizontal pipe with a length of 70 cm and a diameter of 9 cm, covered with 5 cm of mineral wool insulation and jacketed with an impermeable aluminum sheet under surface-convection and radiation heat transfer to the surroundings (27°C). The simulated 100°C vapor supply (0.013 g/s baseline) is prescribed at the axial inlet . The simulation results show the formation of an entrance region with radial condensation and evaporation, a dry region adjacent to the pipe, and low liquid saturation adjacent to the outer boundary. The heat loss in this entrance region is 4 - 7 folds larger than the dry insulation, depending on the inlet moisture flow rate. This increase is predominantly due to the radial evaporation/condensation, i.e., the heat-pipe effect, since the liquid saturation is too small to substantially increase the apparent thermal conductivity . Thus, the radial temperature distribution is noticeably altered by this heat-pipe effect. The entrance region is marked by complete condensation of the injected vapor and has a length and excess heat loss proportional to the vapor injection rate . The test results confirm the entrance region heat-pipe effect signified by large heat loss, temperature rises as a function of angle, and the vapor penetration depth. • Demonstration of heat-pipe effect in wet annular mineral wool insulation. • Heat-pipe effect (radial evaporation/condensation) is induced by axial vapor transport. • Heat-pipe effect causes excess heat loss, many folds over dry insulation. • The inject vapor condenses over a short penetration depth. • Penetration depth is proportional to the vapor injection rate.

Authors

Institutions

Publication Details

Journal
International Journal of Heat and Mass Transfer
Published
2025-03-20
DOI
https://doi.org/10.1016/j.ijheatmasstransfer.2025.126857
Citations
2
Primary Topic
Spacecraft and Cryogenic Technologies
Type
article
Field-Weighted Citation Impact
9.99

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Axial-vapor-flow induced, low-liquid-saturation heat-pipe effect in wet insulation: Simulation and experiment

John C. Williams, Massoud Kaviany, Fan Lu, Bryan Veyera
2 citations
International Journal of Heat and Mass Transfer
Spacecraft and Cryogenic Technologies
9.99
article

Axial-vapor-flow induced, low-liquid-saturation heat-pipe effect in wet insulation: Simulation and experiment

John C. Williams, Massoud Kaviany, Fan Lu, Bryan Veyera
article en
2 citations

Abstract

In field applications, segmented pipe thermal insulation wrappings are susceptible to inter-segment water penetration and its axial transport, which degrades the insulation thermal performance and causes pipe corrosion under insulation (CUI). Through CFD simulation , this axial transport, its local condensation/evaporation and liquid/vapor movement, and the temperature and liquid saturation distributions are predicted. The accompanying experiment (mineral wool insulation) conditions are a horizontal pipe with a length of 70 cm and a diameter of 9 cm, covered with 5 cm of mineral wool insulation and jacketed with an impermeable aluminum sheet under surface-convection and radiation heat transfer to the surroundings (27°C). The simulated 100°C vapor supply (0.013 g/s baseline) is prescribed at the axial inlet . The simulation results show the formation of an entrance region with radial condensation and evaporation, a dry region adjacent to the pipe, and low liquid saturation adjacent to the outer boundary. The heat loss in this entrance region is 4 - 7 folds larger than the dry insulation, depending on the inlet moisture flow rate. This increase is predominantly due to the radial evaporation/condensation, i.e., the heat-pipe effect, since the liquid saturation is too small to substantially increase the apparent thermal conductivity . Thus, the radial temperature distribution is noticeably altered by this heat-pipe effect. The entrance region is marked by complete condensation of the injected vapor and has a length and excess heat loss proportional to the vapor injection rate . The test results confirm the entrance region heat-pipe effect signified by large heat loss, temperature rises as a function of angle, and the vapor penetration depth. • Demonstration of heat-pipe effect in wet annular mineral wool insulation. • Heat-pipe effect (radial evaporation/condensation) is induced by axial vapor transport. • Heat-pipe effect causes excess heat loss, many folds over dry insulation. • The inject vapor condenses over a short penetration depth. • Penetration depth is proportional to the vapor injection rate.

International Journal of Heat and Mass TransferVol. 244
University of Michigan (US), Aspen Aerogels (United States) (US)
University of Michigan
Openalex Percentile: Top 3%
Spacecraft and Cryogenic Technologies
9.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.