Per-Pixel Calibration Based on Multi-View 3D Reconstruction Errors Beyond the Depth of Field

In 3D microscopic imaging, the extremely shallow depth of field presents a challenge for accurate 3D reconstruction in cases of significant defocus. Traditional calibration methods rely on the spatial extraction of feature points to establish spatial 3D information as the optimization objective. However, these methods suffer from reduced extraction accuracy under defocus conditions, which causes degradation of calibration performance. To extend calibration volume without compromising accuracy in defocused scenarios, we propose a per-pixel calibration based on multi-view 3D reconstruction errors. It utilizes 3D reconstruction errors among different binocular setups as an optimization objective. We first analyze multi-view 3D reconstruction error distributions under the poor-accuracy optical model by employing a multi-view microscopic 3D measurement system using telecentric lenses. Subsequently, the 3D proportion model is proposed for implementing our error-based per-pixel calibration, derived as a spatial linear expression directly correlated with the 3D reconstruction error distribution. The experimental results confirm the robust convergence of our method with multiple binocular setups. Near the focus volume, the multi-view 3D reconstruction error remains approximately m (less than 0.5 camera pixel pitch), with absolute accuracy maintained within 0.5% of the measurement range. Beyond tenfold depth of field, the multi-view 3D reconstruction error increases to around m (still less than 2 camera pixel pitches), while absolute accuracy remains within 1% of the measurement range. These high-precision measurement results validate the feasibility and accuracy of our proposed calibration.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Image Processing
Published
2025-01-01
DOI
https://doi.org/10.1109/tip.2025.3551165
Citations
3
Primary Topic
CCD and CMOS Imaging Sensors
Type
article
Field-Weighted Citation Impact
2.19

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Per-Pixel Calibration Based on Multi-View 3D Reconstruction Errors Beyond the Depth of Field

Wenpan Li, Rong Dai, Yunhui Liu
3 citations
IEEE Transactions on Image Processing
CCD and CMOS Imaging Sensors
2.19
article

Per-Pixel Calibration Based on Multi-View 3D Reconstruction Errors Beyond the Depth of Field

Wenpan Li, Rong Dai, Yunhui Liu
article en
3 citations

Abstract

In 3D microscopic imaging, the extremely shallow depth of field presents a challenge for accurate 3D reconstruction in cases of significant defocus. Traditional calibration methods rely on the spatial extraction of feature points to establish spatial 3D information as the optimization objective. However, these methods suffer from reduced extraction accuracy under defocus conditions, which causes degradation of calibration performance. To extend calibration volume without compromising accuracy in defocused scenarios, we propose a per-pixel calibration based on multi-view 3D reconstruction errors. It utilizes 3D reconstruction errors among different binocular setups as an optimization objective. We first analyze multi-view 3D reconstruction error distributions under the poor-accuracy optical model by employing a multi-view microscopic 3D measurement system using telecentric lenses. Subsequently, the 3D proportion model is proposed for implementing our error-based per-pixel calibration, derived as a spatial linear expression directly correlated with the 3D reconstruction error distribution. The experimental results confirm the robust convergence of our method with multiple binocular setups. Near the focus volume, the multi-view 3D reconstruction error remains approximately m (less than 0.5 camera pixel pitch), with absolute accuracy maintained within 0.5% of the measurement range. Beyond tenfold depth of field, the multi-view 3D reconstruction error increases to around m (still less than 2 camera pixel pitches), while absolute accuracy remains within 1% of the measurement range. These high-precision measurement results validate the feasibility and accuracy of our proposed calibration.

IEEE Transactions on Image ProcessingVol. 34
Chinese University of Hong Kong (HK), Huazhong University of Science and Technology (CN)
Research Grants Council, University Grants Committee
Sustainable cities and communities
Openalex Percentile: Top 13%
CCD and CMOS Imaging Sensors
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.