[Animal study results of a novel designed transcatheter mitral valve replacement system].

<b>Objective:</b> To preliminarily assess the biocompatibility and durability of the TruDelta<sup>TM</sup> transcatheter mitral valve replacement (TMVR) system. <b>Method:</b> Six adult sheep were divided into 3 groups based on the duration of follow-up: 30 days (<i>n</i>=1), 90 days (<i>n</i>=3) and 180 days (<i>n</i>=2). The TruDelta<sup>TM</sup> TMVR system was implanted through a transapical approach under transesophageal echocardiographic guidance. The operability of the TMVR system was evaluated using an instrument performance evaluation scale (consisting of 39 items), with scores ranging from 1 (worst) to 10 (best) assigned by the operator. Echocardiography was conducted preoperatively, immediately after surgery, and at 30, 90, and 180 days post-implantation. At the last follow-up time point, the intervention mitral valve membrane and major organs were dissected for observation. The artificial valves were taken for hematoxylin eosin (HE) staining and observed under a scanning electron microscope. <b>Result:</b> All six procedures were successfully completed using 29S size TruDelta<sup>TM</sup> TMVR device. At the final follow-up, echocardiogram demonstrated good valve function without obvious paravalvular leakage, with a transvalvular gradient of (7.8±3.2) mmHg (1 mmHg=0.133 kPa) and a mitral valve orifice area of (1.8±0.2) cm<sup>2</sup>. Autopsy findings revealed no structural valve failure and almost complete endothelialization (>75%) with 90 to 180 days. Both HE staining and scanning electron microscopy confirmed optimal endothelialization of the valve stent. <b>Conclusion:</b> The preclinical animal study indicates that the TruDelta<sup>TM</sup> device exhibits favorable biocompatibility and durability.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2025-03-24
DOI
https://doi.org/10.3760/cma.j.cn112148-20250126-00069
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Animal study results of a novel designed transcatheter mitral valve replacement system].

Zhiling Luo, Chuan Xie, Pengxu Kong, X B Pan et al.
PubMed
Cardiac Valve Diseases and Treatments
article

[Animal study results of a novel designed transcatheter mitral valve replacement system].

Zhiling Luo, Chuan Xie, Pengxu Kong, X B Pan, S Z Wang, Kai Yang, Dingliang Zhu, Hui Jiang, Jie Gao, Shiyu Feng
article en

Abstract

<b>Objective:</b> To preliminarily assess the biocompatibility and durability of the TruDelta<sup>TM</sup> transcatheter mitral valve replacement (TMVR) system. <b>Method:</b> Six adult sheep were divided into 3 groups based on the duration of follow-up: 30 days (<i>n</i>=1), 90 days (<i>n</i>=3) and 180 days (<i>n</i>=2). The TruDelta<sup>TM</sup> TMVR system was implanted through a transapical approach under transesophageal echocardiographic guidance. The operability of the TMVR system was evaluated using an instrument performance evaluation scale (consisting of 39 items), with scores ranging from 1 (worst) to 10 (best) assigned by the operator. Echocardiography was conducted preoperatively, immediately after surgery, and at 30, 90, and 180 days post-implantation. At the last follow-up time point, the intervention mitral valve membrane and major organs were dissected for observation. The artificial valves were taken for hematoxylin eosin (HE) staining and observed under a scanning electron microscope. <b>Result:</b> All six procedures were successfully completed using 29S size TruDelta<sup>TM</sup> TMVR device. At the final follow-up, echocardiogram demonstrated good valve function without obvious paravalvular leakage, with a transvalvular gradient of (7.8±3.2) mmHg (1 mmHg=0.133 kPa) and a mitral valve orifice area of (1.8±0.2) cm<sup>2</sup>. Autopsy findings revealed no structural valve failure and almost complete endothelialization (>75%) with 90 to 180 days. Both HE staining and scanning electron microscopy confirmed optimal endothelialization of the valve stent. <b>Conclusion:</b> The preclinical animal study indicates that the TruDelta<sup>TM</sup> device exhibits favorable biocompatibility and durability.

PubMedVol. 53(3)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Kunming Medical University (CN), Fuwai Yunnan Cardiovascular Hospital (CN)
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.