Research on fault location method for distribution lines based on additional inductance strategy

When a fault occurs on a distribution line, transient fault signals fade quickly, leaving only a short period of time for measurement and sampling. In addition, timing discrepancies between multiple measuring devices affect the accuracy of fault localization. This study proposes a method for fault detection in distribution lines based on an auxiliary inductance approach, where auxiliary inductors are introduced after the trip to provide steady-state fault data for localization. For asymmetrical short-circuit faults, the fault voltage is calculated from current and voltage measurements at both ends of the line, and the ratio of positive to negative sequence voltages is used to compensate for the phase angle and generate fault location functions. For symmetrical short-circuit faults, the voltage ratio between two faulted phases eliminates asynchronous angles, facilitating the derivation of fault location functions. Simulation results show that this method achieves high accuracy and is robust to differences in fault location, transition resistance, fault types, and synchronous angles.

Authors

Institutions

Publication Details

Journal
AIMS energy
Published
2025-01-01
DOI
https://doi.org/10.3934/energy.2025010
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on fault location method for distribution lines based on additional inductance strategy

Jun Lin, Maoshuai He, Zhen Long, Feifei Liu et al.
AIMS energy
Power Systems Fault Detection
article

Research on fault location method for distribution lines based on additional inductance strategy

Jun Lin, Maoshuai He, Zhen Long, Feifei Liu, Weiji Zhou
article en

Abstract

When a fault occurs on a distribution line, transient fault signals fade quickly, leaving only a short period of time for measurement and sampling. In addition, timing discrepancies between multiple measuring devices affect the accuracy of fault localization. This study proposes a method for fault detection in distribution lines based on an auxiliary inductance approach, where auxiliary inductors are introduced after the trip to provide steady-state fault data for localization. For asymmetrical short-circuit faults, the fault voltage is calculated from current and voltage measurements at both ends of the line, and the ratio of positive to negative sequence voltages is used to compensate for the phase angle and generate fault location functions. For symmetrical short-circuit faults, the voltage ratio between two faulted phases eliminates asynchronous angles, facilitating the derivation of fault location functions. Simulation results show that this method achieves high accuracy and is robust to differences in fault location, transition resistance, fault types, and synchronous angles.

AIMS energyVol. 13(2)
Shihezi University (CN), Xinjiang Institute of Engineering (CN)
Climate action
Openalex Percentile: Top 95%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.