Reliability Study of the Stability of a Retaining Wall for Underground Parking Type Structures with Two-storey Basement

The aim of this work is to see whether supports defined as stable by deterministic calculations can automatically be reliable in the geotechnical sense, as is often considered in Senegal. The analysis was carried out on an building project that had to rest on a two-level subsoil in a site requiring underpinning. A deterministic calculation of the project is carried out to verify the stability of the retaining wall with a safety factor. Then, a probabilistic calculation is made to take into account the variability of the characteristics of the soils that will house the retaining structure, with a coefficient of variation of 10%. The reliability index is determined by considering a safety factor threshold value of 1.5. The length of the sheet with reliable stability is then determined. The results show that for a plug length of 1.8 m, both the secant pile wall and the cast wall are stable with a safety factor greater than 1.7. However, the probabilities of failure and the reliability index remain below their thresholds for both the secant pile wall and the cast wall when the plug is 1.8 m long. The supports are stable and reliable when the plug length is 2.8 m for the same materials. In conclusion, a safety factor greater than the limit does not guarantee a reliable structure in deterministic studies.

Authors

Publication Details

Journal
American journal of civil engineering and architecture
Published
2025-03-17
DOI
https://doi.org/10.12691/ajcea-13-1-4
Primary Topic
Geotechnical Engineering and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability Study of the Stability of a Retaining Wall for Underground Parking Type Structures with Two-storey Basement

Déthiè Sarr, André Luis Corrêa, M J Wade, Thierno Lamine Mouhamadou Sakho
American journal of civil engineering and architecture
Geotechnical Engineering and Analysis
article

Reliability Study of the Stability of a Retaining Wall for Underground Parking Type Structures with Two-storey Basement

Déthiè Sarr, André Luis Corrêa, M J Wade, Thierno Lamine Mouhamadou Sakho
article en

Abstract

The aim of this work is to see whether supports defined as stable by deterministic calculations can automatically be reliable in the geotechnical sense, as is often considered in Senegal. The analysis was carried out on an building project that had to rest on a two-level subsoil in a site requiring underpinning. A deterministic calculation of the project is carried out to verify the stability of the retaining wall with a safety factor. Then, a probabilistic calculation is made to take into account the variability of the characteristics of the soils that will house the retaining structure, with a coefficient of variation of 10%. The reliability index is determined by considering a safety factor threshold value of 1.5. The length of the sheet with reliable stability is then determined. The results show that for a plug length of 1.8 m, both the secant pile wall and the cast wall are stable with a safety factor greater than 1.7. However, the probabilities of failure and the reliability index remain below their thresholds for both the secant pile wall and the cast wall when the plug is 1.8 m long. The supports are stable and reliable when the plug length is 2.8 m for the same materials. In conclusion, a safety factor greater than the limit does not guarantee a reliable structure in deterministic studies.

American journal of civil engineering and architectureVol. 13(1)
Sustainable cities and communities
Openalex Percentile: Top 94%
Geotechnical Engineering and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reliability Study of the Stability of a Retaining Wall for Underground Parking Type Structures with Two-storey Basement — Déthiè Sarr, André Luis Corrêa, et al. · American journal of civil engineering and architecture (2025) | TGRS Research Map | TGRS