Development and Validation of AAV Capsids Separation on Specimen Columns for Reproducibility Evaluation of Large‐Scale Chromatographic Monoliths

One of the key challenges in adeno-associated virus (AAV) viral vector manufacturing is the effective and consistent separation of full (F) AAV capsids from undesired non-functional (empty = E, partially filled, etc.) capsids. Typically, at least one chromatography step is used for this purpose in AAV manufacturing. Due to the complexity of viral capsids separation, even a small change in the chromatographic process is reflected in unreproducible results. One solution for robust polishing of full AAV capsids is the highly reproducible (HR) design of chromatographic columns used in this step. Implementation of such columns requires the development of control tests, which efficiently predict column performance for AAV separation. In this paper, the methodology for reproducible separation of empty and full recombinant AAV2/8 (E/F rAAV2/8) capsids was defined using quaternary amine (QA) chromatographic monoliths in a linear potassium chloride (KCl) gradient. The scalability of the procedure was experimentally confirmed on 1, 80, and 800 mL CIMmultus QA columns, where empty capsids eluted at a KCl concentration range of 89.4-91.4 mM. A sampling of the monolith material from the 800 mL CIMmultus QA column and testing it for E/F rAAV2/8 capsid separation in the form of a 200 µL column resulted in a highly comparable elution pattern as obtained with the parent 800 mL column. The principle of sampling material by cutting the parent monolith, packing it in 200 µL columns (specimens) and testing them for E/F rAAV2/8 capsid separation was further developed to demonstrate intra-column homogeneity; batch-to-batch homogeneity; and scalability of CIM QA monoliths. Finally, specimens testing using a validated E/F rAAV2/8 separation method was used to monitor 28 CIMmultus QA production batches (bed volumes between 1 and 8000 mL). E rAAV2/8 capsids eluted at KCl concentration between 89.3 and 95.3 mM for 28 batches, paving the way for commercialization of highly reproducible preparative QA chromatographic monoliths (CIMmultus QA HR).

Authors

Institutions

Publication Details

Journal
Journal of Separation Science
Published
2025-03-01
DOI
https://doi.org/10.1002/jssc.70114
Citations
6
Primary Topic
Virus-based gene therapy research
Type
article
Field-Weighted Citation Impact
10.90
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of AAV Capsids Separation on Specimen Columns for Reproducibility Evaluation of Large‐Scale Chromatographic Monoliths

Tina Simčič, Aleš Štrancar, Sara Rotar, Urh Černigoj et al.
6 citations
Journal of Separation Science
Virus-based gene therapy research
10.90
article

Development and Validation of AAV Capsids Separation on Specimen Columns for Reproducibility Evaluation of Large‐Scale Chromatographic Monoliths

Tina Simčič, Aleš Štrancar, Sara Rotar, Urh Černigoj, Rok Žigon, D. Pavlović, Ines Bergoč, Rok Miklavčič, Jana Vidič, Ažbe Žnidaršič, Dolores Kukanja, Polona Komel, Domen Ipavec, Ana Simčič Zuljan
article en
6 citations

Abstract

One of the key challenges in adeno-associated virus (AAV) viral vector manufacturing is the effective and consistent separation of full (F) AAV capsids from undesired non-functional (empty = E, partially filled, etc.) capsids. Typically, at least one chromatography step is used for this purpose in AAV manufacturing. Due to the complexity of viral capsids separation, even a small change in the chromatographic process is reflected in unreproducible results. One solution for robust polishing of full AAV capsids is the highly reproducible (HR) design of chromatographic columns used in this step. Implementation of such columns requires the development of control tests, which efficiently predict column performance for AAV separation. In this paper, the methodology for reproducible separation of empty and full recombinant AAV2/8 (E/F rAAV2/8) capsids was defined using quaternary amine (QA) chromatographic monoliths in a linear potassium chloride (KCl) gradient. The scalability of the procedure was experimentally confirmed on 1, 80, and 800 mL CIMmultus QA columns, where empty capsids eluted at a KCl concentration range of 89.4-91.4 mM. A sampling of the monolith material from the 800 mL CIMmultus QA column and testing it for E/F rAAV2/8 capsid separation in the form of a 200 µL column resulted in a highly comparable elution pattern as obtained with the parent 800 mL column. The principle of sampling material by cutting the parent monolith, packing it in 200 µL columns (specimens) and testing them for E/F rAAV2/8 capsid separation was further developed to demonstrate intra-column homogeneity; batch-to-batch homogeneity; and scalability of CIM QA monoliths. Finally, specimens testing using a validated E/F rAAV2/8 separation method was used to monitor 28 CIMmultus QA production batches (bed volumes between 1 and 8000 mL). E rAAV2/8 capsids eluted at KCl concentration between 89.3 and 95.3 mM for 28 batches, paving the way for commercialization of highly reproducible preparative QA chromatographic monoliths (CIMmultus QA HR).

Journal of Separation ScienceVol. 48(3)
University of Ljubljana (SI), BIA Separations (Slovenia) (SI)
Openalex Percentile: Top 2%
Virus-based gene therapy research
10.90
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.