Optimalisasi Konfigurasi Fasa Vertikal Pada Saluran Udara Tegangan Ekstra Tinggi

The dangers arising from the 500 kV extra high voltage overhead lines to the surrounding environment can actually be minimized in several ways. One of the methods is to change the configuration of the conductor arrangement. Based on the laws in field theory which state that the magnitude of the field quantity on a charged conductor can differ depending on the distance, area, or volume, an analysis was carried out to understand the effect of the phase arrangement on the electric field intensity under the 500 kV overhead transmission line. The Finite Difference Method uses a numerical approximation to the partial derivative of the differential equation describing the electric field. The use of the Hybrid Tower combines vertical and horizontal designs to achieve a balance between low electric fields and land efficiency. Of the 36 combinations of phase arrangements on transmission lines with a double-circuit vertical configuration, there is a large variation in the resulting field intensity. Information on the phase arrangement that produces the smallest field intensity is very important. The arrangement of 36 (arrangement T1-S1-R1: T2-S2-R2) produces the lowest electric field intensity. Compared with the super bundle arrangement (arrangement R1-S1-T1: R2-S2-T2), there is a decrease in field intensity of up to 45.842%, while compared with the low reactance arrangement (arrangement R1-S1-T1: T2-S2-R2), there is a decrease in field intensity of up to 33.374%.

Authors

Institutions

Publication Details

Journal
ELPOSYS Jurnal Sistem Kelistrikan
Published
2025-02-28
DOI
https://doi.org/10.33795/elposys.v12i1.6848
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimalisasi Konfigurasi Fasa Vertikal Pada Saluran Udara Tegangan Ekstra Tinggi

Dhimas Dhesah Kharisma, Mochammad Mieftah, Aly Imron, Ruwah Joto
ELPOSYS Jurnal Sistem Kelistrikan
Thermal Analysis in Power Transmission
article

Optimalisasi Konfigurasi Fasa Vertikal Pada Saluran Udara Tegangan Ekstra Tinggi

Dhimas Dhesah Kharisma, Mochammad Mieftah, Aly Imron, Ruwah Joto
article en

Abstract

The dangers arising from the 500 kV extra high voltage overhead lines to the surrounding environment can actually be minimized in several ways. One of the methods is to change the configuration of the conductor arrangement. Based on the laws in field theory which state that the magnitude of the field quantity on a charged conductor can differ depending on the distance, area, or volume, an analysis was carried out to understand the effect of the phase arrangement on the electric field intensity under the 500 kV overhead transmission line. The Finite Difference Method uses a numerical approximation to the partial derivative of the differential equation describing the electric field. The use of the Hybrid Tower combines vertical and horizontal designs to achieve a balance between low electric fields and land efficiency. Of the 36 combinations of phase arrangements on transmission lines with a double-circuit vertical configuration, there is a large variation in the resulting field intensity. Information on the phase arrangement that produces the smallest field intensity is very important. The arrangement of 36 (arrangement T1-S1-R1: T2-S2-R2) produces the lowest electric field intensity. Compared with the super bundle arrangement (arrangement R1-S1-T1: R2-S2-T2), there is a decrease in field intensity of up to 45.842%, while compared with the low reactance arrangement (arrangement R1-S1-T1: T2-S2-R2), there is a decrease in field intensity of up to 33.374%.

ELPOSYS Jurnal Sistem KelistrikanVol. 12(1)
State University of Malang (ID)
Openalex Percentile: Top 95%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.