The model to correct for the ion recombination of micro-thin cylindrical ionization chamber in high dose-rate and frequency pulses X-ray beams

Accurate dosimetry is essential for ultrahigh dose-rate (UHDR, >40 Gy/s) irradiations in clinical radiotherapy (RT). Herein, we introduced a prototype of a micro-thin cylindrical ionization chamber (MC-IC) featuring an electrode distance of 0.2 mm, specifically designed for these beams. This study aimed to investigate the ion collection efficiency (ICE) of the MC-IC in high dose-rate and frequency (HDR&F) pulse X-ray beams. A detailed comparison was made among an empirical logistic model, the two-voltage analysis (TVA) method, and the Boag model. As anticipated, the MC-IC successfully measured a mean dose rate of up to 154.5 Gy/s with an ICE of 98.6 %. We found that the empirical logistic model is well-suited for the MC-IC, whereas the TVA method and Boag model exhibit an underestimation of ICE in HDR&F beams. Therefore, Boag Model 3 with a free-electron fraction of 0.5 < P < 0.6 and a modified TVA equation with a free-electron fraction of P = 0.6 must be considered. For the TVA method, a voltage ratio ≤2 is recommended. In conclusion, this study complemented and refined a dosimetric methodology for evaluating the collection efficiency correction factor for special ionization chambers. • A MC-IC designed for UDR&F X-ray beams, achieving a mean dose rate of up to 154.5 Gy/s with an ICE of 98.6%. • We assessed three ion recombination models for MC-IC and the empirical logistic model is suitable for MI-IC. • A voltage ratio ≤ 2 and Equation (9) with p = 0.6 Model 3is recommended for the TVA mothed in HDR&F X-ray beams. • A free-electron fraction of 0.5 < p < 0.6 must be considered for the Boag Model 3 in HDR&F X-ray beams.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2025-03-17
DOI
https://doi.org/10.1016/j.nima.2025.170434
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The model to correct for the ion recombination of micro-thin cylindrical ionization chamber in high dose-rate and frequency pulses X-ray beams

Sen Bai, Wanchang LAI, Yanmei HAO
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Radiation Therapy and Dosimetry
article

The model to correct for the ion recombination of micro-thin cylindrical ionization chamber in high dose-rate and frequency pulses X-ray beams

Sen Bai, Wanchang LAI, Yanmei HAO
article en

Abstract

Accurate dosimetry is essential for ultrahigh dose-rate (UHDR, >40 Gy/s) irradiations in clinical radiotherapy (RT). Herein, we introduced a prototype of a micro-thin cylindrical ionization chamber (MC-IC) featuring an electrode distance of 0.2 mm, specifically designed for these beams. This study aimed to investigate the ion collection efficiency (ICE) of the MC-IC in high dose-rate and frequency (HDR&F) pulse X-ray beams. A detailed comparison was made among an empirical logistic model, the two-voltage analysis (TVA) method, and the Boag model. As anticipated, the MC-IC successfully measured a mean dose rate of up to 154.5 Gy/s with an ICE of 98.6 %. We found that the empirical logistic model is well-suited for the MC-IC, whereas the TVA method and Boag model exhibit an underestimation of ICE in HDR&F beams. Therefore, Boag Model 3 with a free-electron fraction of 0.5 < P < 0.6 and a modified TVA equation with a free-electron fraction of P = 0.6 must be considered. For the TVA method, a voltage ratio ≤2 is recommended. In conclusion, this study complemented and refined a dosimetric methodology for evaluating the collection efficiency correction factor for special ionization chambers. • A MC-IC designed for UDR&F X-ray beams, achieving a mean dose rate of up to 154.5 Gy/s with an ICE of 98.6%. • We assessed three ion recombination models for MC-IC and the empirical logistic model is suitable for MI-IC. • A voltage ratio ≤ 2 and Equation (9) with p = 0.6 Model 3is recommended for the TVA mothed in HDR&F X-ray beams. • A free-electron fraction of 0.5 < p < 0.6 must be considered for the Boag Model 3 in HDR&F X-ray beams.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentVol. 1075
University of Electronic Science and Technology of China (CN), Sichuan University (CN), Chengdu University of Technology (CN), West China Hospital of Sichuan University (CN), Sichuan Cancer Hospital (CN)
Affordable and clean energy
Openalex Percentile: Top 92%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.