IN-VIVO ANALYSIS OF OXIDATIVE STRESS IN AESTHETIC COATED ORTHODONTIC ARCH-WIRES & BRACKETS

Objectives: To assess in vivo the oxidative damage that aesthetic coated arch-wires causes by measuring 8OHdG (8-hydroxydeoxyguanosine ) as an oxidative marker to detect the level of oxidative stress generation.Materials and Methods: About 80 patients of ages 15-30 years enrolled in the study having fi xed orthodontic treatment were divided into control (patients with NiTi wire) and experimental groups including patients with wires coated in PTFE, epoxy resin, and rhodium. Saliva samples were collected with an unstimulated saliva collection method at two intervals. The first sample was collected before the bonding process and insertion of the arch-wires and the second sample was collected four weeks after the insertion of arch-wires. The samples were kept in storage at -80°C, and the amounts of 8-OHdG were measured by ELISA analysis.Results: The salivary 8-OhdG level in all groups was measured at day 0 and the end of week 4. At day 0, It was 1.60±43 ng/ml in the NiTi group,1.60±0.52 ng/ml in the epoxy resin group, 1.70±0.12 ng/ml in the rhodium group and 1.63±0.40 ng/ml in PTFE group. After 4 weeks, it was 3.6810.47 ng/ml in the NiTi group, 3.50±0.77 ng/ml in the epoxy resin group, 3.06±0.70 ng/ml in the rhodium group and 2.75±0.72 ng/ml in PTFE group, p = 0.812) This demonstrated that while there was no noteworthy variation in the groups' mean 8-OHdG levels at day 0, there was at week 4. Post hoc Tukey test revealed that PTFE-coated arch-wires and Rhodium group had significantly lower 8-OHdG levels compared to NiTi and Epoxy resin-coated arch-wire. Salivary 8-OHdG levels increased significantly after 4 weeks of arch-wire use in all groups.Conclusion: This study suggests that PTFE-coated arch-wires are the most biocompatible among the coated arch-wires studied.

Authors

Institutions

Publication Details

Journal
Journal of Khyber College of Dentistry
Published
2025-03-18
DOI
https://doi.org/10.33279/jkcd.v15i01.757
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IN-VIVO ANALYSIS OF OXIDATIVE STRESS IN AESTHETIC COATED ORTHODONTIC ARCH-WIRES & BRACKETS

Husnain Abbas, Assad Abbas, Iffat Batool Syed, Muhammad Azeem et al.
Journal of Khyber College of Dentistry
Dental materials and restorations
article

IN-VIVO ANALYSIS OF OXIDATIVE STRESS IN AESTHETIC COATED ORTHODONTIC ARCH-WIRES & BRACKETS

Husnain Abbas, Assad Abbas, Iffat Batool Syed, Muhammad Azeem, Saira Khalid, Zahra Faisal
article en

Abstract

Objectives: To assess in vivo the oxidative damage that aesthetic coated arch-wires causes by measuring 8OHdG (8-hydroxydeoxyguanosine ) as an oxidative marker to detect the level of oxidative stress generation.Materials and Methods: About 80 patients of ages 15-30 years enrolled in the study having fi xed orthodontic treatment were divided into control (patients with NiTi wire) and experimental groups including patients with wires coated in PTFE, epoxy resin, and rhodium. Saliva samples were collected with an unstimulated saliva collection method at two intervals. The first sample was collected before the bonding process and insertion of the arch-wires and the second sample was collected four weeks after the insertion of arch-wires. The samples were kept in storage at -80°C, and the amounts of 8-OHdG were measured by ELISA analysis.Results: The salivary 8-OhdG level in all groups was measured at day 0 and the end of week 4. At day 0, It was 1.60±43 ng/ml in the NiTi group,1.60±0.52 ng/ml in the epoxy resin group, 1.70±0.12 ng/ml in the rhodium group and 1.63±0.40 ng/ml in PTFE group. After 4 weeks, it was 3.6810.47 ng/ml in the NiTi group, 3.50±0.77 ng/ml in the epoxy resin group, 3.06±0.70 ng/ml in the rhodium group and 2.75±0.72 ng/ml in PTFE group, p = 0.812) This demonstrated that while there was no noteworthy variation in the groups' mean 8-OHdG levels at day 0, there was at week 4. Post hoc Tukey test revealed that PTFE-coated arch-wires and Rhodium group had significantly lower 8-OHdG levels compared to NiTi and Epoxy resin-coated arch-wire. Salivary 8-OHdG levels increased significantly after 4 weeks of arch-wire use in all groups.Conclusion: This study suggests that PTFE-coated arch-wires are the most biocompatible among the coated arch-wires studied.

Journal of Khyber College of DentistryVol. 15(01)
Collège Montmorency (CA)
Openalex Percentile: Top 95%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

IN-VIVO ANALYSIS OF OXIDATIVE STRESS IN AESTHETIC COATED ORTHODONTIC ARCH-WIRES & BRACKETS — Husnain Abbas, Assad Abbas, et al. · Journal of Khyber College of Dentistry (2025) | TGRS Research Map | TGRS