Towards Safer and Healthier Childcare Facilities: Evaluating Environmental and Safety Standards in Daycare Centers in Dubai

The increasing demand for childcare facilities in Dubai, UAE, which is driven by urban expansion and workforce growth, calls for a focus on establishing standardized environmental and safety benchmarks. This study evaluated 28 daycare centers categorized by size (large, medium, and small), focusing on indoor environmental quality (IEQ), cleanliness, safety, and space utilization. Findings revealed that while air pollutants like carbon monoxide (0.57 ppm) and formaldehyde (45.8 µg/m3) remained within acceptable limits, carbon dioxide levels (averaging 1048.2 ppm, particularly in large centers) exceeded regulatory standards due to high occupancy rates and inadequate ventilation. Large facilities demonstrated better compliance with kitchen safety (8.8/10) and lighting efficiency, while small centers scored higher in restroom cleanliness (20.8/24, evaluated using eight criteria on a structured 3-point scale). However, spatial accessibility remained a critical challenge across all facility sizes, particularly regarding accommodations for individuals with disabilities. Additionally, excessive lighting levels (717.2 lux) and high indoor temperatures (27–28 °C) further highlighted the need for tailored guidelines. The study emphasizes improving ventilation systems, promoting universal design principles, and targeted investments to address these disparities. By aligning regulatory frameworks with actionable recommendations, this study provides insights for policymakers to enhance the safety, inclusivity, and environmental quality of daycare infrastructure in Dubai.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-03-18
DOI
https://doi.org/10.3390/buildings15060953
Citations
1
Primary Topic
Pediatric health and respiratory diseases
Type
article
Field-Weighted Citation Impact
2.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards Safer and Healthier Childcare Facilities: Evaluating Environmental and Safety Standards in Daycare Centers in Dubai

Gamal El Samanoudy, Chuloh Jung, Naglaa Sami Abdelaziz Mahmoud
1 citations
Buildings
Pediatric health and respiratory diseases
2.52
article

Towards Safer and Healthier Childcare Facilities: Evaluating Environmental and Safety Standards in Daycare Centers in Dubai

Gamal El Samanoudy, Chuloh Jung, Naglaa Sami Abdelaziz Mahmoud
article en
1 citations

Abstract

The increasing demand for childcare facilities in Dubai, UAE, which is driven by urban expansion and workforce growth, calls for a focus on establishing standardized environmental and safety benchmarks. This study evaluated 28 daycare centers categorized by size (large, medium, and small), focusing on indoor environmental quality (IEQ), cleanliness, safety, and space utilization. Findings revealed that while air pollutants like carbon monoxide (0.57 ppm) and formaldehyde (45.8 µg/m3) remained within acceptable limits, carbon dioxide levels (averaging 1048.2 ppm, particularly in large centers) exceeded regulatory standards due to high occupancy rates and inadequate ventilation. Large facilities demonstrated better compliance with kitchen safety (8.8/10) and lighting efficiency, while small centers scored higher in restroom cleanliness (20.8/24, evaluated using eight criteria on a structured 3-point scale). However, spatial accessibility remained a critical challenge across all facility sizes, particularly regarding accommodations for individuals with disabilities. Additionally, excessive lighting levels (717.2 lux) and high indoor temperatures (27–28 °C) further highlighted the need for tailored guidelines. The study emphasizes improving ventilation systems, promoting universal design principles, and targeted investments to address these disparities. By aligning regulatory frameworks with actionable recommendations, this study provides insights for policymakers to enhance the safety, inclusivity, and environmental quality of daycare infrastructure in Dubai.

BuildingsVol. 15(6)
Prince Mohammad bin Fahd University (SA), Ajman University (AE)
Openalex Percentile: Top 15%
Pediatric health and respiratory diseases
2.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.