Design of hardware interfaces for the LHC Phase-2 CMS ECAL Barrel Safety System

Abstract The CMS Electromagnetic Calorimeter (ECAL) uses lead tungstate scintillating crystals to measure the energy of electrons and photons produced at the Large Hadron Collider (LHC). The High Luminosity upgrade of the LHC (HL-LHC) at CERN during the LHC Long Shutdown 3 imposes significant challenges for its experiments. The higher luminosity changes the environmental conditions in which the ECAL detector will operate. In this contribution the upgrade plans and preliminary designs to accommodate the new operational requirements of the CMS ECAL Barrel Safety System are summarized, including the design and development of hardware components for Resistance Temperature Detector (RTD) interfacing and the interlock control.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-03-01
DOI
https://doi.org/10.1088/1748-0221/20/03/c03027
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of hardware interfaces for the LHC Phase-2 CMS ECAL Barrel Safety System

Krzysztof Stachon, Raúl Jiménez Estupiñán, L. Cokic, N. Härringer et al.
Journal of Instrumentation
Particle Detector Development and Performance
article

Design of hardware interfaces for the LHC Phase-2 CMS ECAL Barrel Safety System

Krzysztof Stachon, Raúl Jiménez Estupiñán, L. Cokic, N. Härringer, M. Mijic, G. Dissertori, P. Milenovic, W. Lustermann, P. Adzic, D. Jovanovic, E. Auffray Hillemanns
article en

Abstract

Abstract The CMS Electromagnetic Calorimeter (ECAL) uses lead tungstate scintillating crystals to measure the energy of electrons and photons produced at the Large Hadron Collider (LHC). The High Luminosity upgrade of the LHC (HL-LHC) at CERN during the LHC Long Shutdown 3 imposes significant challenges for its experiments. The higher luminosity changes the environmental conditions in which the ECAL detector will operate. In this contribution the upgrade plans and preliminary designs to accommodate the new operational requirements of the CMS ECAL Barrel Safety System are summarized, including the design and development of hardware components for Resistance Temperature Detector (RTD) interfacing and the interlock control.

Journal of InstrumentationVol. 20(03)
University of Belgrade (RS), Institute for Biomedical Engineering (CH), Institute of Particle Physics (CA), European Organization for Nuclear Research (CH)
Openalex Percentile: Top 97%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.