Experimental Validation of Current Distribution in Intense Relativistic Electron Beams From a Coaxial Dual-Ring Cathode

This article presents a comprehensive simulation study and the first experimental investigation of a coaxial nested dual-ring cathode (CNDC) for dual-frequency high-power microwave (HPM) generation. Operating under a low solenoidal guiding magnetic field of 0.6 T, the CNDC successfully emitted and transmitted dual-ring intense relativistic electron beams (IREBs) with high transmission efficiencies. The experimental results closely validated the predictions of particle-in-cell (PIC) simulations, with total emission currents measured at approximately 15.8 kA, aligning well with the 15.6 and 15.5 kA predicted by the 2-D and 3-D simulations, respectively. Furthermore, the experimentally observed beam current distribution between the outer and inner rings closely adhered to design expectations, demonstrating the stability and reliability of the CNDC for dual-frequency HPM applications.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Electron Devices
Published
2025-03-18
DOI
https://doi.org/10.1109/ted.2025.3548999
Citations
1
Primary Topic
Gyrotron and Vacuum Electronics Research
Type
article
Field-Weighted Citation Impact
1.25
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Validation of Current Distribution in Intense Relativistic Electron Beams From a Coaxial Dual-Ring Cathode

Fanbo Zeng, Xinbing Cheng, Junpu Ling, Juntao He et al.
1 citations
IEEE Transactions on Electron Devices
Gyrotron and Vacuum Electronics Research
1.25
article

Experimental Validation of Current Distribution in Intense Relativistic Electron Beams From a Coaxial Dual-Ring Cathode

Fanbo Zeng, Xinbing Cheng, Junpu Ling, Juntao He, Lei Wang, Lili Song, Xingfu Gao, Rong Chen
article en
1 citations

Abstract

This article presents a comprehensive simulation study and the first experimental investigation of a coaxial nested dual-ring cathode (CNDC) for dual-frequency high-power microwave (HPM) generation. Operating under a low solenoidal guiding magnetic field of 0.6 T, the CNDC successfully emitted and transmitted dual-ring intense relativistic electron beams (IREBs) with high transmission efficiencies. The experimental results closely validated the predictions of particle-in-cell (PIC) simulations, with total emission currents measured at approximately 15.8 kA, aligning well with the 15.6 and 15.5 kA predicted by the 2-D and 3-D simulations, respectively. Furthermore, the experimentally observed beam current distribution between the outer and inner rings closely adhered to design expectations, demonstrating the stability and reliability of the CNDC for dual-frequency HPM applications.

IEEE Transactions on Electron DevicesVol. 72(5)
National University of Defense Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 23%
Gyrotron and Vacuum Electronics Research
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.