New Paradigm for Beehive Monitoring System Using Infrared and Power Line Communication

In recent years, smart beehive monitoring has attracted attention due to its highly profitable industry. However, colony collapse disorder (CCD) syndrome, which is described by the sudden disappearance of the bee colony, severely affects the honey bee industry in most countries of the world. The causes of CCD are not verified, but electromagnetic interference (EMI) is the possible one that appears in most beehive monitoring systems. Based on this motivation, this paper presents a new paradigm for beehive monitoring utilizing the proposed system consisting of a host module, multiple sensor modules, and relay modules. Each sensor module is responsible for collecting the in-hive parameters of each beehive such as temperature, humidity, hive weight, carbon dioxide, oxygen, and entrance counts. The collected sensor data are then transmitted to the relay module by infrared (IR) communication to avoid EMI. The relay module integrates the IR receiver and power line communication (PLC) transmitter technologies, where the former is used to receive optical signals with in-hive parameters, and the latter is used to transform the abovementioned signals into PLC interface. Moreover, a host module is introduced to aim at receiving the signals from multiple relay modules by the PLC interface. The distances of IR communication and PLC are determined through simulation results under the target bit error rate of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$10^{-3}$</tex-math></inline-formula> to provide accurate in-hive parameters with negligible interference from multiple beehives. Experimental results also show that the proposed system could meet the requirements of real-time and long-term data collection and transmission.

Authors

Institutions

Publication Details

Journal
IEEE photonics journal
Published
2025-03-18
DOI
https://doi.org/10.1109/jphot.2025.3552600
Citations
1
Primary Topic
IoT-based Smart Home Systems
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New Paradigm for Beehive Monitoring System Using Infrared and Power Line Communication

Wei-Wen Hu, Taiyu Chen, Da-Huei Lee, Y. Lee
1 citations
IEEE photonics journal
IoT-based Smart Home Systems
0.73
article

New Paradigm for Beehive Monitoring System Using Infrared and Power Line Communication

Wei-Wen Hu, Taiyu Chen, Da-Huei Lee, Y. Lee
article en
1 citations

Abstract

In recent years, smart beehive monitoring has attracted attention due to its highly profitable industry. However, colony collapse disorder (CCD) syndrome, which is described by the sudden disappearance of the bee colony, severely affects the honey bee industry in most countries of the world. The causes of CCD are not verified, but electromagnetic interference (EMI) is the possible one that appears in most beehive monitoring systems. Based on this motivation, this paper presents a new paradigm for beehive monitoring utilizing the proposed system consisting of a host module, multiple sensor modules, and relay modules. Each sensor module is responsible for collecting the in-hive parameters of each beehive such as temperature, humidity, hive weight, carbon dioxide, oxygen, and entrance counts. The collected sensor data are then transmitted to the relay module by infrared (IR) communication to avoid EMI. The relay module integrates the IR receiver and power line communication (PLC) transmitter technologies, where the former is used to receive optical signals with in-hive parameters, and the latter is used to transform the abovementioned signals into PLC interface. Moreover, a host module is introduced to aim at receiving the signals from multiple relay modules by the PLC interface. The distances of IR communication and PLC are determined through simulation results under the target bit error rate of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$10^{-3}$</tex-math></inline-formula> to provide accurate in-hive parameters with negligible interference from multiple beehives. Experimental results also show that the proposed system could meet the requirements of real-time and long-term data collection and transmission.

IEEE photonics journalVol. 17(2)
National Formosa University (TW), Southern Taiwan University of Science and Technology (TW)
Affordable and clean energy
Openalex Percentile: Top 30%
IoT-based Smart Home Systems
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.