Pattern Recognition Method for Detecting Partial Discharge in Oil-Paper Insulation Equipment Using Optical F-P Sensor Array Based on KAN-CNN Algorithm

Ultrasound detection can promptly identify partial discharge (PD) faults inside power transformer by using fiber-optic Fabry-Perot (F-P) array sensors. This paper presents a new design scheme for a wideband acousto-optic direct-coupled F-P sensor. Indirect-coupled F-P sensors have a narrow, highly sensitive response region, and direct-coupled F-P sensors have a wide band response from 1 to 200 kHz. We constructed a PD database by simulating different PD signals in oil tank. We proposed learnable KAN kernel to replace traditional CNN kernel and introduced KAN as a replacement for the ReLU function. Furthermore, we conducted pattern recognition research with a convolutional depth of only 6 layers. The test accuracy on oil tank dataset reached 98.7% for KAN Convolution + ReLU and 99.5% for KAN Convolution + KAN. The validation accuracy achieved by inputting PD signals measured from a real 220 kV power transformer into the two models was 97.5% and 98.75%, respectively.

Authors

Institutions

Publication Details

Journal
Journal of Lightwave Technology
Published
2025-03-18
DOI
https://doi.org/10.1109/jlt.2025.3552628
Citations
41
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
49.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pattern Recognition Method for Detecting Partial Discharge in Oil-Paper Insulation Equipment Using Optical F-P Sensor Array Based on KAN-CNN Algorithm

Weigen Chen, Ruimin Song, Zhixian Zhang, Hong Liu et al.
41 citations
Journal of Lightwave Technology
Advanced Sensor and Control Systems
49.80
article

Pattern Recognition Method for Detecting Partial Discharge in Oil-Paper Insulation Equipment Using Optical F-P Sensor Array Based on KAN-CNN Algorithm

Weigen Chen, Ruimin Song, Zhixian Zhang, Hong Liu, Yuxuan Song, Jianxin Wang, Haoyuan Tian
article en
41 citations

Abstract

Ultrasound detection can promptly identify partial discharge (PD) faults inside power transformer by using fiber-optic Fabry-Perot (F-P) array sensors. This paper presents a new design scheme for a wideband acousto-optic direct-coupled F-P sensor. Indirect-coupled F-P sensors have a narrow, highly sensitive response region, and direct-coupled F-P sensors have a wide band response from 1 to 200 kHz. We constructed a PD database by simulating different PD signals in oil tank. We proposed learnable KAN kernel to replace traditional CNN kernel and introduced KAN as a replacement for the ReLU function. Furthermore, we conducted pattern recognition research with a convolutional depth of only 6 layers. The test accuracy on oil tank dataset reached 98.7% for KAN Convolution + ReLU and 99.5% for KAN Convolution + KAN. The validation accuracy achieved by inputting PD signals measured from a real 220 kV power transformer into the two models was 97.5% and 98.75%, respectively.

Journal of Lightwave TechnologyVol. 43(12)
Chongqing University of Posts and Telecommunications (CN), Chongqing University (CN), Chongqing University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 0%
Advanced Sensor and Control Systems
49.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.