High-Performance and Intelligent Digital Active Sensor System for Epilepsy Information Acquisition and Classification
In this article, we present a performance-enhanced digital active sensor system consisting of a quantum-enhanced active sensor (that frontend micro-electro-mechanical-systems (MEMS) electrode coupled with readout circuits) and an artificial intelligence (AI) empowered engine, which is used for detecting dual-mode neural signals sensitively and classifying about epilepsy disease accurately, respectively. First, digital active sensors with improved sensitivity and reliability include: 1) the active sensor’s bare microelectrode array (MEA) manufactured from the perspective of quantum mechanics; 2) the high-resolution active sensor’s information quantizer for weak neural electrophysiological signal quantization with noise depression techniques; and 3) transmitting power of the radio transmitter reduces by employing bitstream compression with fast rolling-in hash table method. Second, structure and subsystem re-synthesizable AI engine with flexible and scalability abilities. For bare microelectrodes, on the one side, an optimized stack Si<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub>N<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</sub>/SiO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> dielectric thin film of the bare microelectrode can prevent leakage caused by Fowler-Nordheim (FN) tunneling and stress-induced leakage-current (SILC) effects, also solve the microelectrode peeling problem caused by mechanical stress. In addition, nanomaterial Pt with nanostructure modified on the surface of Pt/Ti alloy of the bare microelectrode for reconstructing local Fermi level, increasing charge injection, and boosting electrocatalytic with continuous-descent-energy-step (CDES) approach. For the neurotransmitter microelectrode manufactured based on the bare microelectrode, the tested linear range is 0.998° and sensitivity is 0.0072 pA/<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu $ </tex-math></inline-formula>m<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>. Energy consumption of the entire digital active sensor is less than 70 mW under a 1.8-V power and electrophysiological spike resolution is <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.93~\mu $ </tex-math></inline-formula>V. The recognition accuracy of the resynthesizable AI engine arrives at 99.74% using a random forest model, which is appropriate for epilepsy disease classification.
Authors
- G. Z. Liu (ORCID: https://orcid.org/0000-0003-4358-3309)
- Tianlai Li (ORCID: https://orcid.org/0000-0003-3218-7909)
- Zekun Jiang (ORCID: https://orcid.org/0000-0002-3178-7761)
- Zhenpeng Liu (ORCID: https://orcid.org/0000-0002-7466-4622)
- Wenlong Yao (ORCID: https://orcid.org/0000-0001-8501-365X)
- Xiaodong Chen (ORCID: https://orcid.org/0000-0002-3312-1664)
- Jianhui Sun
Institutions
- Chinese Academy of Sciences (CN)
- Sichuan University (CN)
- China Electronics Technology Group Corporation (CN)
- Shandong Normal University (CN)
- Chengdu University (CN)
Publication Details
- Journal
- IEEE Sensors Journal
- Published
- 2025-03-18
- DOI
- https://doi.org/10.1109/jsen.2025.3550187
- Citations
- 1
- Primary Topic
- EEG and Brain-Computer Interfaces
- Type
- article
- Field-Weighted Citation Impact
- 1.43