High-Performance and Intelligent Digital Active Sensor System for Epilepsy Information Acquisition and Classification

In this article, we present a performance-enhanced digital active sensor system consisting of a quantum-enhanced active sensor (that frontend micro-electro-mechanical-systems (MEMS) electrode coupled with readout circuits) and an artificial intelligence (AI) empowered engine, which is used for detecting dual-mode neural signals sensitively and classifying about epilepsy disease accurately, respectively. First, digital active sensors with improved sensitivity and reliability include: 1) the active sensor’s bare microelectrode array (MEA) manufactured from the perspective of quantum mechanics; 2) the high-resolution active sensor’s information quantizer for weak neural electrophysiological signal quantization with noise depression techniques; and 3) transmitting power of the radio transmitter reduces by employing bitstream compression with fast rolling-in hash table method. Second, structure and subsystem re-synthesizable AI engine with flexible and scalability abilities. For bare microelectrodes, on the one side, an optimized stack Si<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub>N<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</sub>/SiO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> dielectric thin film of the bare microelectrode can prevent leakage caused by Fowler-Nordheim (FN) tunneling and stress-induced leakage-current (SILC) effects, also solve the microelectrode peeling problem caused by mechanical stress. In addition, nanomaterial Pt with nanostructure modified on the surface of Pt/Ti alloy of the bare microelectrode for reconstructing local Fermi level, increasing charge injection, and boosting electrocatalytic with continuous-descent-energy-step (CDES) approach. For the neurotransmitter microelectrode manufactured based on the bare microelectrode, the tested linear range is 0.998° and sensitivity is 0.0072 pA/<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu $ </tex-math></inline-formula>m<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>. Energy consumption of the entire digital active sensor is less than 70 mW under a 1.8-V power and electrophysiological spike resolution is <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.93~\mu $ </tex-math></inline-formula>V. The recognition accuracy of the resynthesizable AI engine arrives at 99.74% using a random forest model, which is appropriate for epilepsy disease classification.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-03-18
DOI
https://doi.org/10.1109/jsen.2025.3550187
Citations
1
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Performance and Intelligent Digital Active Sensor System for Epilepsy Information Acquisition and Classification

G. Z. Liu, Tianlai Li, Zekun Jiang, Zhenpeng Liu et al.
1 citations
IEEE Sensors Journal
EEG and Brain-Computer Interfaces
1.43
article

High-Performance and Intelligent Digital Active Sensor System for Epilepsy Information Acquisition and Classification

G. Z. Liu, Tianlai Li, Zekun Jiang, Zhenpeng Liu, Wenlong Yao, Xiaodong Chen, Jianhui Sun
article en
1 citations

Abstract

In this article, we present a performance-enhanced digital active sensor system consisting of a quantum-enhanced active sensor (that frontend micro-electro-mechanical-systems (MEMS) electrode coupled with readout circuits) and an artificial intelligence (AI) empowered engine, which is used for detecting dual-mode neural signals sensitively and classifying about epilepsy disease accurately, respectively. First, digital active sensors with improved sensitivity and reliability include: 1) the active sensor’s bare microelectrode array (MEA) manufactured from the perspective of quantum mechanics; 2) the high-resolution active sensor’s information quantizer for weak neural electrophysiological signal quantization with noise depression techniques; and 3) transmitting power of the radio transmitter reduces by employing bitstream compression with fast rolling-in hash table method. Second, structure and subsystem re-synthesizable AI engine with flexible and scalability abilities. For bare microelectrodes, on the one side, an optimized stack Si<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub>N<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</sub>/SiO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> dielectric thin film of the bare microelectrode can prevent leakage caused by Fowler-Nordheim (FN) tunneling and stress-induced leakage-current (SILC) effects, also solve the microelectrode peeling problem caused by mechanical stress. In addition, nanomaterial Pt with nanostructure modified on the surface of Pt/Ti alloy of the bare microelectrode for reconstructing local Fermi level, increasing charge injection, and boosting electrocatalytic with continuous-descent-energy-step (CDES) approach. For the neurotransmitter microelectrode manufactured based on the bare microelectrode, the tested linear range is 0.998° and sensitivity is 0.0072 pA/<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu $ </tex-math></inline-formula>m<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>. Energy consumption of the entire digital active sensor is less than 70 mW under a 1.8-V power and electrophysiological spike resolution is <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.93~\mu $ </tex-math></inline-formula>V. The recognition accuracy of the resynthesizable AI engine arrives at 99.74% using a random forest model, which is appropriate for epilepsy disease classification.

IEEE Sensors JournalVol. 25(9)
Chinese Academy of Sciences (CN), Sichuan University (CN), China Electronics Technology Group Corporation (CN), Shandong Normal University (CN), Chengdu University (CN)
Openalex Percentile: Top 22%
EEG and Brain-Computer Interfaces
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.