A Single-XO Dual-Output Frequency Reference Featuring Adaptive RTC Calibration Achieving 0.63 ppm/°C Temperature Coefficient From –40 °C to 125 °C
This brief presents a trimming-free single-crystal dual-output (SXDO) frequency reference featuring adaptive binary-search (ABS)-based real-time clock (RTC) calibration. The on-demand 16-MHz crystal oscillator (XO) can serve as a frequency reference to calibrate the always-on 1-MHz on-chip RTC. To suppress the inaccurate calibration in the wake of the oscillator’s jitter, we propose the ABS-based calibration to adjust the accumulation cycles depending on the frequency difference between the XO and RTC to enhance the comparison accuracy. Further, we reuse the accurately calibrated RTC signal as a reference to generate a 16-MHz pulse train and inject it into the crystal to expedite the XO startup. We implemented the proposed SXDO frequency reference in a 65-nm CMOS process. The RTC achieves a temperature coefficient of 0.63 ppm/°C across -40 to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$125~^{\circ }$ </tex-math></inline-formula>C. The calibration takes <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$720~\mu $ </tex-math></inline-formula>s while consuming 40.3 nJ of energy. The XO, benefitting from the RTC-assisted constant injection with improved accuracy, can exert injection of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$60~\mu $ </tex-math></inline-formula>s and attain a startup time of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$145~\mu $ </tex-math></inline-formula>s, with a startup energy of 9.9 nJ.
Authors
- Ka‐Meng Lei (ORCID: https://orcid.org/0000-0003-1781-971X)
- Pui‐In Mak (ORCID: https://orcid.org/0000-0002-3579-8740)
- Rui Luo (ORCID: https://orcid.org/0000-0003-4131-8202)
- Rui P. Martins (ORCID: https://orcid.org/0000-0003-2821-648X)
Institutions
- University of Macau (MO)
- Institute of Microelectronics (CN)
Publication Details
- Journal
- IEEE Transactions on Circuits & Systems II Express Briefs
- Published
- 2025-03-18
- DOI
- https://doi.org/10.1109/tcsii.2025.3552650
- Citations
- 1
- Primary Topic
- Calibration and Measurement Techniques
- Type
- article
- Field-Weighted Citation Impact
- 4.99
Funders
- Universidade de Macau
- Fundo para o Desenvolvimento das Ciências e da Tecnologia