Establishing reference ranges for Century Clot® coagulation and platelet function analyzer in third trimester of pregnancy women: An observational study

This study aimed to establish reference ranges of the Century Clot® coagulation and platelet function analyzer (CPA) for pregnant women at ≥37 weeks of gestation. A total of 300 patients were included in this study. Use Century Clot coagulation and platelet function analyzer to analyze the venous blood of the subjects. Numerical values were recorded and differences in coagulation function indicators between normal full-term pregnant women and healthy non-pregnant women were compared, including activated clotting time (ACT), fibrin coagulation rate (CR), and platelet function (PF). Significant differences were observed in the results of relevant indicators measured using the CPA between women with late pregnancy and healthy non-pregnant women (P < .0001). The reference range for parameters of CPA in late pregnancy (pregnancy > 37 weeks) is determined by percentile method as follows: ACT 75.10 to 112.00 seconds, CR 23.20 to 46.98 mm/minute, PF 3.10 to 5.10 units. Compared with non-pregnant women, ACT in late-pregnancy women detected by the CPA decreased physiologically, while fibrin CR and PF increased. The establishment of a specific reference interval for ACT, CR, and PF in pregnant women is valuable for clinical practice.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2025-03-14
DOI
https://doi.org/10.1097/md.0000000000041883
Primary Topic
Pregnancy and preeclampsia studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishing reference ranges for Century Clot® coagulation and platelet function analyzer in third trimester of pregnancy women: An observational study

Shaoqiang Huang, Meng Ge, Tingting Sun
Medicine
Pregnancy and preeclampsia studies
article

Establishing reference ranges for Century Clot® coagulation and platelet function analyzer in third trimester of pregnancy women: An observational study

Shaoqiang Huang, Meng Ge, Tingting Sun
article en

Abstract

This study aimed to establish reference ranges of the Century Clot® coagulation and platelet function analyzer (CPA) for pregnant women at ≥37 weeks of gestation. A total of 300 patients were included in this study. Use Century Clot coagulation and platelet function analyzer to analyze the venous blood of the subjects. Numerical values were recorded and differences in coagulation function indicators between normal full-term pregnant women and healthy non-pregnant women were compared, including activated clotting time (ACT), fibrin coagulation rate (CR), and platelet function (PF). Significant differences were observed in the results of relevant indicators measured using the CPA between women with late pregnancy and healthy non-pregnant women (P < .0001). The reference range for parameters of CPA in late pregnancy (pregnancy > 37 weeks) is determined by percentile method as follows: ACT 75.10 to 112.00 seconds, CR 23.20 to 46.98 mm/minute, PF 3.10 to 5.10 units. Compared with non-pregnant women, ACT in late-pregnancy women detected by the CPA decreased physiologically, while fibrin CR and PF increased. The establishment of a specific reference interval for ACT, CR, and PF in pregnant women is valuable for clinical practice.

MedicineVol. 104(11)
Obstetrics and Gynecology Hospital of Fudan University (CN)
Good health and well-being
Openalex Percentile: Top 93%
Pregnancy and preeclampsia studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.