Research on the distributed capacitance for high-voltage key components on CRAFT NNBI

Abstract The negative ion based neutral beam injector (NNBI) with a beam energy of 400 keV is one of the subsystems at the Comprehensive Research fAcility for Fusion Technology (CRAFT) in China. The distributed capacitance of the high-voltage components is an important basis for the design of surge suppression devices at CRAFT NNBI. This study conducted calculations of distributed capacitance for the key components, including the high-voltage deck, transmission line and isolation transformer in the power supply system using the finite element method. The relationship between the high-voltage deck (HVD) distributed capacitance and the distance from the wall is discussed. The differences in distributed capacitance and energy storage between non-coaxial and coaxial transmission lines are also debated. Finally, the capacitance between the primary and secondary windings of the −400 kV isolation transformer, as well as between the secondary winding and the oil tank casing, was calculated.

Authors

Institutions

Publication Details

Journal
Plasma Science and Technology
Published
2025-03-18
DOI
https://doi.org/10.1088/2058-6272/adc23b
Citations
1
Primary Topic
Engineering and Test Systems
Type
article
Field-Weighted Citation Impact
1.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the distributed capacitance for high-voltage key components on CRAFT NNBI

Lizhen Liang, Wei Wei, Junjun Pan, Caichao Jiang et al.
1 citations
Plasma Science and Technology
Engineering and Test Systems
1.21
article

Research on the distributed capacitance for high-voltage key components on CRAFT NNBI

Lizhen Liang, Wei Wei, Junjun Pan, Caichao Jiang, Yuanlai Xie, Shiyong Chen, Sheng Liu, Zhimin Liu, Rongmin Bai, Y. Qu, Бо Лю
article en
1 citations

Abstract

Abstract The negative ion based neutral beam injector (NNBI) with a beam energy of 400 keV is one of the subsystems at the Comprehensive Research fAcility for Fusion Technology (CRAFT) in China. The distributed capacitance of the high-voltage components is an important basis for the design of surge suppression devices at CRAFT NNBI. This study conducted calculations of distributed capacitance for the key components, including the high-voltage deck, transmission line and isolation transformer in the power supply system using the finite element method. The relationship between the high-voltage deck (HVD) distributed capacitance and the distance from the wall is discussed. The differences in distributed capacitance and energy storage between non-coaxial and coaxial transmission lines are also debated. Finally, the capacitance between the primary and secondary windings of the −400 kV isolation transformer, as well as between the secondary winding and the oil tank casing, was calculated.

Plasma Science and TechnologyVol. 27(4)
University of Science and Technology of China (CN), Chinese Academy of Sciences (CN), Hefei Institutes of Physical Science (CN), Institute of Plasma Physics (CN), Nanjing University of Aeronautics and Astronautics (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 24%
Engineering and Test Systems
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.