Investigating the Design of a Photoplethysmography Device for Vital Sign Monitoring

There exists a distinct lack of publicly available literature addressing the most effective hardware design for photoplethysmography (PPG) devices for clinical and domestic applications. In this article, this problem was addressed by investigating the hardware design configuration of a PPG device, with particular emphasis on the light source wavelength, light source brightness, number of light sources, photodetector lens shape, and sensor-to-skin contact pressure. A participant study was conducted to collect cardiovascular metric data from 110 participants with varying skin tones, which was used to determine the most promising hardware configuration of the PPG device. It was concluded that the device had little bias to skin tone, with only a 3.82 dB variance over all the skin tones tested.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-03-18
DOI
https://doi.org/10.3390/s25061875
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigating the Design of a Photoplethysmography Device for Vital Sign Monitoring

Rensu P. Theart, Anneri Appel
1 citations
Sensors
Non-Invasive Vital Sign Monitoring
0.67
article

Investigating the Design of a Photoplethysmography Device for Vital Sign Monitoring

Rensu P. Theart, Anneri Appel
article en
1 citations

Abstract

There exists a distinct lack of publicly available literature addressing the most effective hardware design for photoplethysmography (PPG) devices for clinical and domestic applications. In this article, this problem was addressed by investigating the hardware design configuration of a PPG device, with particular emphasis on the light source wavelength, light source brightness, number of light sources, photodetector lens shape, and sensor-to-skin contact pressure. A participant study was conducted to collect cardiovascular metric data from 110 participants with varying skin tones, which was used to determine the most promising hardware configuration of the PPG device. It was concluded that the device had little bias to skin tone, with only a 3.82 dB variance over all the skin tones tested.

SensorsVol. 25(6)
Stellenbosch University (ZA)
Good health and well-being
Openalex Percentile: Top 34%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.