Heparin and Gelatin Co-Functionalized Polyurethane Artificial Blood Vessel for Improving Anticoagulation and Biocompatibility

The primary challenges in the tissue engineering of small-diameter artificial blood vessels include inadequate mechanical properties and insufficient anticoagulation capabilities. To address these challenges, urea-pyrimidone (Upy)-based polyurethane elastomers (PIIU-B) were synthesized by incorporating quadruple hydrogen bonding within the polymer backbone. The synthesis process employed poly(L-lactide-ε-caprolactone) (PLCL) as the soft segment, while di-(isophorone diisocyanate)-Ureido pyrimidinone (IUI) and isophorone diisocyanate (IPDI) were utilized as the hard segment. The resulting PIIU-B small-diameter artificial blood vessel with a diameter of 4 mm was fabricated using the electrospinning technique, achieving an optimized IUI/IPDI composition ratio of 1:1. Enhanced by multiple hydrogen bonds, the vessels exhibited a robust elastic modulus of 12.45 MPa, an extracellular matrix (ECM)-mimetic nanofiber morphology, and a high porosity of 41.31%. Subsequently, the PIIU-B vessel underwent dual-functionalization with low-molecular-weight heparin and gelatin via ultraviolet (UV) crosslinking (designated as PIIU-B@LHep/Gel), which conferred superior biocompatibility and exceptional anticoagulation properties. The study revealed improved anti-platelet adhesion characteristics as well as a prolonged activated partial thromboplastin time (APTT) of 157.2 s and thrombin time (TT) of 64.2 s in vitro. Following a seven-day subcutaneous implantation, the PIIU-B@LHep/Gel vessel exhibited excellent biocompatibility, evidenced by complete integration with the surrounding peri-implant tissue, significant cell infiltration, and collagen formation in vivo. Consequently, polyurethane-based artificial blood vessels, reinforced by multiple hydrogen bonds and dual-functionalized with heparin and gelatin, present as promising candidates for vascular tissue engineering.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2025-03-18
DOI
https://doi.org/10.3390/bioengineering12030304
Citations
3
Primary Topic
Electrospun Nanofibers in Biomedical Applications
Type
article
Field-Weighted Citation Impact
1.79

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heparin and Gelatin Co-Functionalized Polyurethane Artificial Blood Vessel for Improving Anticoagulation and Biocompatibility

Danting Li, Jimin Zhang, Pingsheng Huang, Jingzhe Guo et al.
3 citations
Bioengineering
Electrospun Nanofibers in Biomedical Applications
1.79
article

Heparin and Gelatin Co-Functionalized Polyurethane Artificial Blood Vessel for Improving Anticoagulation and Biocompatibility

Danting Li, Jimin Zhang, Pingsheng Huang, Jingzhe Guo, Junxian Zhang, Meihui Zhong, Yuxuan Gu, Xiaozhe Yan
article en
3 citations

Abstract

The primary challenges in the tissue engineering of small-diameter artificial blood vessels include inadequate mechanical properties and insufficient anticoagulation capabilities. To address these challenges, urea-pyrimidone (Upy)-based polyurethane elastomers (PIIU-B) were synthesized by incorporating quadruple hydrogen bonding within the polymer backbone. The synthesis process employed poly(L-lactide-ε-caprolactone) (PLCL) as the soft segment, while di-(isophorone diisocyanate)-Ureido pyrimidinone (IUI) and isophorone diisocyanate (IPDI) were utilized as the hard segment. The resulting PIIU-B small-diameter artificial blood vessel with a diameter of 4 mm was fabricated using the electrospinning technique, achieving an optimized IUI/IPDI composition ratio of 1:1. Enhanced by multiple hydrogen bonds, the vessels exhibited a robust elastic modulus of 12.45 MPa, an extracellular matrix (ECM)-mimetic nanofiber morphology, and a high porosity of 41.31%. Subsequently, the PIIU-B vessel underwent dual-functionalization with low-molecular-weight heparin and gelatin via ultraviolet (UV) crosslinking (designated as PIIU-B@LHep/Gel), which conferred superior biocompatibility and exceptional anticoagulation properties. The study revealed improved anti-platelet adhesion characteristics as well as a prolonged activated partial thromboplastin time (APTT) of 157.2 s and thrombin time (TT) of 64.2 s in vitro. Following a seven-day subcutaneous implantation, the PIIU-B@LHep/Gel vessel exhibited excellent biocompatibility, evidenced by complete integration with the surrounding peri-implant tissue, significant cell infiltration, and collagen formation in vivo. Consequently, polyurethane-based artificial blood vessels, reinforced by multiple hydrogen bonds and dual-functionalized with heparin and gelatin, present as promising candidates for vascular tissue engineering.

BioengineeringVol. 12(3)
Hebei University of Technology (CN), Chinese Academy of Medical Sciences & Peking Union Medical College (CN)
National Natural Science Foundation of China
Clean water and sanitation
Openalex Percentile: Top 17%
Electrospun Nanofibers in Biomedical Applications
1.79
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.