The accuracy of measuring confined fluid properties using white light interferometry

Thin-film interferometry (type: Fabry-Pérot) with visible white-light illumination can detect sub-nanometer changes in optical path and, therefore, be utilized to study the thickness and refractive index (RI) of nano-confined fluids at a typical resolution ≤ λ/104. This type of white light interferometry is understandably at the core of the surface forces apparatus technique, where two mica sheets with identical thickness (e.g., 1-5 µm) are used to confine a fluid between their surfaces at nanometer separations and measure surface forces as a function of surface separation. In this context, the absolute accuracy of white light interferometry has received little attention historically, although accuracy is the key limiting factor for certain types of experiments, such as the measurements of RI of nanometer thin fluid films. At its root, the accuracy of interferometric RI measurement critically depends on exactly detecting secondary spectral modulations. The following spectral evaluation requires a theory based on an interferometer definition that consists of accurate values for thickness and dispersive RI for all optical layers involved. This work aims at complementing the partially existing literature toward a systematic treatment of the most relevant accuracy-limiting factors; in addition, systematic errors in the interferometer definition include the choice of dispersive RI mathematical model or other experimentally variable factors like the mechanical deformations occurring inside the interferometer under the influence of surface forces. We conclude that an accurate optical description of the layers contributing most to the optical path (e.g., mica surfaces) is currently the leading source of systematic error and that the present methodology of thin film interferometry is not sufficiently accurate to detect and quantify a change of density <10% in a nanometer confined fluid.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-03-01
DOI
https://doi.org/10.1063/5.0245879
Citations
2
Primary Topic
Force Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.49
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The accuracy of measuring confined fluid properties using white light interferometry

Urs Schütz, Manfred Heuberger, Erwin Hack, Monika Góra et al.
2 citations
Review of Scientific Instruments
Force Microscopy Techniques and Applications
2.49
article

The accuracy of measuring confined fluid properties using white light interferometry

Urs Schütz, Manfred Heuberger, Erwin Hack, Monika Góra, Peng Zhang
article en
2 citations

Abstract

Thin-film interferometry (type: Fabry-Pérot) with visible white-light illumination can detect sub-nanometer changes in optical path and, therefore, be utilized to study the thickness and refractive index (RI) of nano-confined fluids at a typical resolution ≤ λ/104. This type of white light interferometry is understandably at the core of the surface forces apparatus technique, where two mica sheets with identical thickness (e.g., 1-5 µm) are used to confine a fluid between their surfaces at nanometer separations and measure surface forces as a function of surface separation. In this context, the absolute accuracy of white light interferometry has received little attention historically, although accuracy is the key limiting factor for certain types of experiments, such as the measurements of RI of nanometer thin fluid films. At its root, the accuracy of interferometric RI measurement critically depends on exactly detecting secondary spectral modulations. The following spectral evaluation requires a theory based on an interferometer definition that consists of accurate values for thickness and dispersive RI for all optical layers involved. This work aims at complementing the partially existing literature toward a systematic treatment of the most relevant accuracy-limiting factors; in addition, systematic errors in the interferometer definition include the choice of dispersive RI mathematical model or other experimentally variable factors like the mechanical deformations occurring inside the interferometer under the influence of surface forces. We conclude that an accurate optical description of the layers contributing most to the optical path (e.g., mica surfaces) is currently the leading source of systematic error and that the present methodology of thin film interferometry is not sufficiently accurate to detect and quantify a change of density <10% in a nanometer confined fluid.

Review of Scientific InstrumentsVol. 96(3)
ETH Zurich (CH), Swiss Federal Laboratories for Materials Science and Technology (CH), King Abdullah University of Science and Technology (SA)
Openalex Percentile: Top 13%
Force Microscopy Techniques and Applications
2.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.