Real-time monitoring of ssDNA binding using a fiber optic LSPR microfluidic platform

In this paper, we present the development of a localized surface plasmon resonance (LSPR) sensor for the detection of single-stranded DNA (ssDNA). The LSPR chip was fabricated using gold nanoparticles (AuNPs) with a diameter of 80 nm. It was integrated with a microfluidic chamber to ensure stable measurements. We employed data processing techniques to fit the absorbance curve and extract the resonance wavelength, significantly reducing noise and achieving a 100-fold improvement in signal quality. The fabricated LSPR chips demonstrated a bulk refractive index sensitivity of approximately 85–90 nm/RIU. This paper outlines a robust methodology for reliable LSPR measurements based on cheap and readily accessible instruments. We have shown successfully real-time binding between Poly(T 20 ) and Poly(A 20 ), sensitive down to a concentration of 2 nM, while maintaining signal fluctuations 10 times lower than the shift in resonance wavelength without using any complex signal amplification technique. The sensor exhibits a limit of detection (LOD) of 0.75 nM. The proposed method shows potential for high-sensitivity and reliable real-time detection of smaller biomolecules, environmental pollutants, foodborne pathogens, toxins, and disease biomarkers. • We present the development of a LSPR sensor for the detection of ssDNA. • The LSPR chip was integrated with a microfluidic chamber for stable measurements. • The sensor exhibits a limit of detection (LOD) of 0.75 nM. • This paper presents a reliable LSPR measurement method without any sophisticated instruments. • The proposed method shows potential for high-sensitivity and reliable real-time detection of smaller biomolecules.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics X
Published
2025-03-18
DOI
https://doi.org/10.1016/j.biosx.2025.100613
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-time monitoring of ssDNA binding using a fiber optic LSPR microfluidic platform

Vivek Semwal, Jakob Janting, Ole Bang, Asbjørn Moltke
1 citations
Biosensors and Bioelectronics X
Advanced biosensing and bioanalysis techniques
0.81
article

Real-time monitoring of ssDNA binding using a fiber optic LSPR microfluidic platform

Vivek Semwal, Jakob Janting, Ole Bang, Asbjørn Moltke
article en
1 citations

Abstract

In this paper, we present the development of a localized surface plasmon resonance (LSPR) sensor for the detection of single-stranded DNA (ssDNA). The LSPR chip was fabricated using gold nanoparticles (AuNPs) with a diameter of 80 nm. It was integrated with a microfluidic chamber to ensure stable measurements. We employed data processing techniques to fit the absorbance curve and extract the resonance wavelength, significantly reducing noise and achieving a 100-fold improvement in signal quality. The fabricated LSPR chips demonstrated a bulk refractive index sensitivity of approximately 85–90 nm/RIU. This paper outlines a robust methodology for reliable LSPR measurements based on cheap and readily accessible instruments. We have shown successfully real-time binding between Poly(T 20 ) and Poly(A 20 ), sensitive down to a concentration of 2 nM, while maintaining signal fluctuations 10 times lower than the shift in resonance wavelength without using any complex signal amplification technique. The sensor exhibits a limit of detection (LOD) of 0.75 nM. The proposed method shows potential for high-sensitivity and reliable real-time detection of smaller biomolecules, environmental pollutants, foodborne pathogens, toxins, and disease biomarkers. • We present the development of a LSPR sensor for the detection of ssDNA. • The LSPR chip was integrated with a microfluidic chamber for stable measurements. • The sensor exhibits a limit of detection (LOD) of 0.75 nM. • This paper presents a reliable LSPR measurement method without any sophisticated instruments. • The proposed method shows potential for high-sensitivity and reliable real-time detection of smaller biomolecules.

Biosensors and Bioelectronics XVol. 24
Manipal Academy of Higher Education (IN), Technical University of Denmark (DK)
Grønt Udviklings- og Demonstrations Program
Affordable and clean energy
Openalex Percentile: Top 30%
Advanced biosensing and bioanalysis techniques
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.