Low-frequency capacitance and mass-change of un-conditioned Nafion-coated electrodes – towards calibration-free aAg(I) ion sensing in pure water

Here, we propose a method for chemical sensing of Ag + ions in pure water by utilizing single-use and un-conditioned Nafion-coated Au electrodes together with capacitive and mass transduction principles. Ag + ions were accumulated and simultaneously Ag was deposited in the Nafion membrane at an applied potential of −0.6 V vs. Ag/AgCl, followed by electrochemical impedance spectroscopy (EIS) to obtain the low-frequency capacitance. After Ag deposition, the resulting change in the low-frequency capacitance at 10 mHz of the Nafion-coated Au was determined with respect to the activity of Ag + ion ( a Ag+ ) in solution in the range of loga Ag+ = −11 to −2. The precision of the low-frequency capacitance was improved by utilizing spin-coated thin-layer Nafion membrane with applied single frequency at 1 Hz. Under identical experimental conditions, the capacitive response of the Nafion/Au electrode was larger than that of a Nafion-coated glassy carbon (Nafion/GC) electrode, indicating better electrocatalytic activity of Au than GC towards Ag + . Based on quartz crystal microbalance (QCM) measurements, the mass change due to Ag deposition at Nafion/Au was linearly proportional to loga Ag + in the range of −5 to −2. Both EIS and QCM methods show a response that correlates with the concentration or activity of Ag + ions in pure water, which might give a possibility for calibration-free determination of Ag + without any electrode conditioning needed. • Low frequency capacitance of Nafion/Au is in correlation with loga Ag+ . • The precision of low frequency capacitance can be improved. • Nafion/Au behaves better electrocatalytic activity than GC towards Ag + . • Nafion QCM mass detection limit of loga Ag+ is −5.06. • Nafion QCM mass change is linearly proportional to loga Ag+ .

Authors

Institutions

Publication Details

Journal
Electrochemistry Communications
Published
2025-03-17
DOI
https://doi.org/10.1016/j.elecom.2025.107911
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-frequency capacitance and mass-change of un-conditioned Nafion-coated electrodes – towards calibration-free aAg(I) ion sensing in pure water

Dongxue Han, Johan Bobacka, Xuliang Lin, Tao Song et al.
1 citations
Electrochemistry Communications
Analytical Chemistry and Sensors
0.74
article

Low-frequency capacitance and mass-change of un-conditioned Nafion-coated electrodes – towards calibration-free aAg(I) ion sensing in pure water

Dongxue Han, Johan Bobacka, Xuliang Lin, Tao Song, Tingting Han, Li Niu, Sini Chen
article en
1 citations

Abstract

Here, we propose a method for chemical sensing of Ag + ions in pure water by utilizing single-use and un-conditioned Nafion-coated Au electrodes together with capacitive and mass transduction principles. Ag + ions were accumulated and simultaneously Ag was deposited in the Nafion membrane at an applied potential of −0.6 V vs. Ag/AgCl, followed by electrochemical impedance spectroscopy (EIS) to obtain the low-frequency capacitance. After Ag deposition, the resulting change in the low-frequency capacitance at 10 mHz of the Nafion-coated Au was determined with respect to the activity of Ag + ion ( a Ag+ ) in solution in the range of loga Ag+ = −11 to −2. The precision of the low-frequency capacitance was improved by utilizing spin-coated thin-layer Nafion membrane with applied single frequency at 1 Hz. Under identical experimental conditions, the capacitive response of the Nafion/Au electrode was larger than that of a Nafion-coated glassy carbon (Nafion/GC) electrode, indicating better electrocatalytic activity of Au than GC towards Ag + . Based on quartz crystal microbalance (QCM) measurements, the mass change due to Ag deposition at Nafion/Au was linearly proportional to loga Ag + in the range of −5 to −2. Both EIS and QCM methods show a response that correlates with the concentration or activity of Ag + ions in pure water, which might give a possibility for calibration-free determination of Ag + without any electrode conditioning needed. • Low frequency capacitance of Nafion/Au is in correlation with loga Ag+ . • The precision of low frequency capacitance can be improved. • Nafion/Au behaves better electrocatalytic activity than GC towards Ag + . • Nafion QCM mass detection limit of loga Ag+ is −5.06. • Nafion QCM mass change is linearly proportional to loga Ag+ .

Electrochemistry CommunicationsVol. 175
Åbo Akademi University (FI), Guangdong University of Technology (CN), Sun Yat-sen University (CN), South China University of Technology (CN)
Clean water and sanitation
Openalex Percentile: Top 36%
Analytical Chemistry and Sensors
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.