Performance Validation of a New Portable Ophthalmic Ultrasound Device

Purpose This study aimed to compare a new indigenous portable ophthalmic ultrasound device with an industry-standard multinational device for its accuracy, precision, and potential use in home care. Methods Axial and transverse images were compared for the same eye at the same visit using the India-made and multinational-made industry-standard devices for several common and rare vitreoretinal conditions in a large referral center in India. All images were obtained by the same optometrist on the same day using the India- and multinational-made devices in that sequence. Two third-year retina fellow investigators masked to the diagnosis and device analyzed the images for inter- and intra-observer accuracy of clinical diagnosis. The clinical diagnosis was compared with a senior vitreoretinal faculty member. Results The study included 118 eyes scanned once with each device. The overall accuracy was 88.9% for the portable India-made device and 85.5% for the multinational-made device. The inter-observer agreement and kappa were the same for the India-made and multinational-made devices; these were 91.52% and 0.83, respectively. The intra-observer agreement for various diagnoses for grader 1 was 95% (Cohen's kappa: 0.89) and for grader 2 was 93.3% (Cohen's kappa: 0.86). Conclusion The India-made portable ophthalmic ultrasound device was non-inferior to the multinational-made device in clinical utility. Its advantages were portability, lesser cost, and ease of use, which make the device more suitable for home eye care.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-03-17
DOI
https://doi.org/10.7759/cureus.80711
Primary Topic
Ophthalmology and Visual Health Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Validation of a New Portable Ophthalmic Ultrasound Device

Rajeev Reddy Pappuru, Kiruthika Kannan, Saarang Hansraj, Kannan Umadevi Venkataraju et al.
Cureus
Ophthalmology and Visual Health Research
article

Performance Validation of a New Portable Ophthalmic Ultrasound Device

Rajeev Reddy Pappuru, Kiruthika Kannan, Saarang Hansraj, Kannan Umadevi Venkataraju, Akash Belenje, Taraprasad Das, Dhanush Pandya, Ravichandran Kondusamy, Jayasankar Sagadevan
article en

Abstract

Purpose This study aimed to compare a new indigenous portable ophthalmic ultrasound device with an industry-standard multinational device for its accuracy, precision, and potential use in home care. Methods Axial and transverse images were compared for the same eye at the same visit using the India-made and multinational-made industry-standard devices for several common and rare vitreoretinal conditions in a large referral center in India. All images were obtained by the same optometrist on the same day using the India- and multinational-made devices in that sequence. Two third-year retina fellow investigators masked to the diagnosis and device analyzed the images for inter- and intra-observer accuracy of clinical diagnosis. The clinical diagnosis was compared with a senior vitreoretinal faculty member. Results The study included 118 eyes scanned once with each device. The overall accuracy was 88.9% for the portable India-made device and 85.5% for the multinational-made device. The inter-observer agreement and kappa were the same for the India-made and multinational-made devices; these were 91.52% and 0.83, respectively. The intra-observer agreement for various diagnoses for grader 1 was 95% (Cohen's kappa: 0.89) and for grader 2 was 93.3% (Cohen's kappa: 0.86). Conclusion The India-made portable ophthalmic ultrasound device was non-inferior to the multinational-made device in clinical utility. Its advantages were portability, lesser cost, and ease of use, which make the device more suitable for home eye care.

CureusVol. 17(3)
L V Prasad Eye Institute (IN), Engineering Associates (United States) (US)
Affordable and clean energy
Openalex Percentile: Top 91%
Ophthalmology and Visual Health Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.