Landau distribution-based regularized algorithm for reconstruction of electron beam energy spectrum using depth dose distributions in targeted materials

Abstract Assuming the beam spectrum at the accelerator output follows a Gaussian distribution and its attenuation in air is described by a Landau distribution, the ill-posed problem of electron energy spectrum reconstruction using depth-dose distribution was reduced to finding the electron spectrum at the phantom surface as a convolution of the Landau and Gaussian distributions. The algorithm proposed in the study uses the experimentally measured depth dose distributions generated by Varian TrueBeam medical accelerator operating at 6 MeV and 9 MeV modes in water-equivalint and aluminium phantoms and reconstructs the electron spectra in targeted materials. The algorithm uses reference depth dose distributions from monoenergetic electrons calculated using Geant4 toolkit. It was found that the spectra reconstructed using experimental depth dose distributions in solid water and aluminium differ by less than 5%, and reconstructed depth dose distributions corresponding to the reconstructed spectra deviate from experimentally measured ones by no more than 5%.

Authors

Institutions

Publication Details

Journal
Physica Scripta
Published
2025-03-17
DOI
https://doi.org/10.1088/1402-4896/adc17a
Citations
1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
1.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Landau distribution-based regularized algorithm for reconstruction of electron beam energy spectrum using depth dose distributions in targeted materials

А. А. Николаева, В. С. Ипатова, U. A. Bliznyuk, A. P. Chernyaev et al.
1 citations
Physica Scripta
Radiation Detection and Scintillator Technologies
1.88
article

Landau distribution-based regularized algorithm for reconstruction of electron beam energy spectrum using depth dose distributions in targeted materials

А. А. Николаева, В. С. Ипатова, U. A. Bliznyuk, A. P. Chernyaev, S. A. Zolotov, Ф. Р. Студеникин, A. D. Nikitchenko, Natalia Antipina, P. Yu. Borshchegovskaya, Maria Toropygina
article en
1 citations

Abstract

Abstract Assuming the beam spectrum at the accelerator output follows a Gaussian distribution and its attenuation in air is described by a Landau distribution, the ill-posed problem of electron energy spectrum reconstruction using depth-dose distribution was reduced to finding the electron spectrum at the phantom surface as a convolution of the Landau and Gaussian distributions. The algorithm proposed in the study uses the experimentally measured depth dose distributions generated by Varian TrueBeam medical accelerator operating at 6 MeV and 9 MeV modes in water-equivalint and aluminium phantoms and reconstructs the electron spectra in targeted materials. The algorithm uses reference depth dose distributions from monoenergetic electrons calculated using Geant4 toolkit. It was found that the spectra reconstructed using experimental depth dose distributions in solid water and aluminium differ by less than 5%, and reconstructed depth dose distributions corresponding to the reconstructed spectra deviate from experimentally measured ones by no more than 5%.

Physica ScriptaVol. 100(4)
Sechenov University (RU), Lomonosov Moscow State University (RU), Burdenko Neurosurgery Institute (RU)
Russian Science Foundation
Openalex Percentile: Top 19%
Radiation Detection and Scintillator Technologies
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.