Study of a Sensitive and Selective Electrochemical Biosensor for Glucose Based on Bi2Ru2O7 Pyrochlore Clusters Combined with MWCNTs

The development of sensitive, selective, and reliable glucose biosensors remains a persistent challenge in clinical diagnostics. In this study, we exploited the advantageous (electro)catalytic properties of bismuth ruthenate (Bi2Ru2O7) pyrochlore clusters, known for their high surface activity and metallic-like conductivity, and the favorable physicochemical properties of multi-walled carbon nanotubes (MWCNTs) by combining them with glucose oxidase (GOD) in a sensitive and selective disposable glucose biosensor. The integration of Bi2Ru2O7 enabled an enhanced and more reproducible response of the biosensor along with fast and improved communication between the supporting electrode and the upper biosensing layer. The architecture of the biosensor involves the deposition of an MWCNT layer on a ferrocyanide-modified screen-printed carbon electrode (FCN-SPCE), followed by the application of a biorecognition layer including GOD and Bi2Ru2O7 clusters. The voltammetric biosensor showed excellent electroanalytical performance, capable of detecting low glucose concentrations with a detection limit of 40 µM along with a linear response across the examined concentration range of 1.0–20.0 mM. The biosensor exhibited good reproducibility with a relative standard deviation (RSD) of 1.2% and interference-free operation against several of the most common interfering compounds. The practical applicability of the biosensor was demonstrated by the determination of glucose in a real serum sample spiked with different concentrations of glucose.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2025-03-15
DOI
https://doi.org/10.3390/chemosensors13030109
Citations
3
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
2.19

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of a Sensitive and Selective Electrochemical Biosensor for Glucose Based on Bi2Ru2O7 Pyrochlore Clusters Combined with MWCNTs

Matjaž Finšgar, Kristijan Vidović, Nikola Tasić, M. Žunić et al.
3 citations
Chemosensors
Electrochemical sensors and biosensors
2.19
article

Study of a Sensitive and Selective Electrochemical Biosensor for Glucose Based on Bi2Ru2O7 Pyrochlore Clusters Combined with MWCNTs

Matjaž Finšgar, Kristijan Vidović, Nikola Tasić, M. Žunić, Jelena Isailović, Samo B. Hočevar, Aleksandra Dapčević
article en
3 citations

Abstract

The development of sensitive, selective, and reliable glucose biosensors remains a persistent challenge in clinical diagnostics. In this study, we exploited the advantageous (electro)catalytic properties of bismuth ruthenate (Bi2Ru2O7) pyrochlore clusters, known for their high surface activity and metallic-like conductivity, and the favorable physicochemical properties of multi-walled carbon nanotubes (MWCNTs) by combining them with glucose oxidase (GOD) in a sensitive and selective disposable glucose biosensor. The integration of Bi2Ru2O7 enabled an enhanced and more reproducible response of the biosensor along with fast and improved communication between the supporting electrode and the upper biosensing layer. The architecture of the biosensor involves the deposition of an MWCNT layer on a ferrocyanide-modified screen-printed carbon electrode (FCN-SPCE), followed by the application of a biorecognition layer including GOD and Bi2Ru2O7 clusters. The voltammetric biosensor showed excellent electroanalytical performance, capable of detecting low glucose concentrations with a detection limit of 40 µM along with a linear response across the examined concentration range of 1.0–20.0 mM. The biosensor exhibited good reproducibility with a relative standard deviation (RSD) of 1.2% and interference-free operation against several of the most common interfering compounds. The practical applicability of the biosensor was demonstrated by the determination of glucose in a real serum sample spiked with different concentrations of glucose.

ChemosensorsVol. 13(3)
University of Maribor (SI), University of Belgrade (RS), National Institute of Chemistry (SI), Institute for Multidisciplinary Research
Javna Agencija za Raziskovalno Dejavnost RS
Openalex Percentile: Top 13%
Electrochemical sensors and biosensors
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.