Von Mises Equivalent Stresses Developed in Fixed Partial Denture Infrastructures on Implants According to Changes in Their Prosthetic Materials

Fixed partial prosthesis with a suspended intermediate element on implants (pontic) can reduce costs and/or make viable cases with limitations in the supporting bone structure. Greater biomechanical demands on the system and variation in the materials of the prosthetic infrastructures could interfere with the stresses developed. This study aimed to verify and compare these stresses in prosthetic infrastructures according to the variation in the material used to make them. The von Mises equivalent stresses (VMES) were qualitatively and quantitatively analyzed in the most significant stress areas in these infrastructures, which were divided into different experimental groups: cobalt-chrome (CoCr); nickel-chromium (NiCr); titanium (Ti); zirconia (Zr); lithium disilicate (LD); type IV gold (Au); and acrylic resin (AR). They were then analyzed using the finite element method (FEM) to verify the stresses developed, as well as their intensity and scope, using a color scale generated in a virtual computer analysis environment (Ansys Workbench Software). The results allowed us to observe that different stresses are generated in the material used in the prosthetic infrastructure, depending on its variation. A directly proportional relationship was found between the stiffness of the material and the stresses generated, meaning that greater rigidity results in greater stresses. It is important to highlight that there was no imminent risk of harm to the biomechanics in any varying situation in the infrastructure material, except acrylic resin, which reached stress thresholds in the prosthetic structure close to its maximum flexural resistance.

Authors

Institutions

Publication Details

Journal
Journal of Oral Implantology
Published
2025-03-17
DOI
https://doi.org/10.1563/aaid-joi-d-24-00153
Citations
1
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
1.79
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Von Mises Equivalent Stresses Developed in Fixed Partial Denture Infrastructures on Implants According to Changes in Their Prosthetic Materials

Silvio Pedro da Silva Sakamoto, Pedro Henrique Justino Oliveira Limírio, Luiz Renato Paranhos, Ana Paula Macedo et al.
1 citations
Journal of Oral Implantology
Dental Implant Techniques and Outcomes
1.79
article

Von Mises Equivalent Stresses Developed in Fixed Partial Denture Infrastructures on Implants According to Changes in Their Prosthetic Materials

Silvio Pedro da Silva Sakamoto, Pedro Henrique Justino Oliveira Limírio, Luiz Renato Paranhos, Ana Paula Macedo, Marcelo Bighetti Toniollo, Andrea Sayuri Silveira Dias Terada, Renato Canevari Dutra da Silva, Kalyta Esteves Martins dos Reis
article en
1 citations

Abstract

Fixed partial prosthesis with a suspended intermediate element on implants (pontic) can reduce costs and/or make viable cases with limitations in the supporting bone structure. Greater biomechanical demands on the system and variation in the materials of the prosthetic infrastructures could interfere with the stresses developed. This study aimed to verify and compare these stresses in prosthetic infrastructures according to the variation in the material used to make them. The von Mises equivalent stresses (VMES) were qualitatively and quantitatively analyzed in the most significant stress areas in these infrastructures, which were divided into different experimental groups: cobalt-chrome (CoCr); nickel-chromium (NiCr); titanium (Ti); zirconia (Zr); lithium disilicate (LD); type IV gold (Au); and acrylic resin (AR). They were then analyzed using the finite element method (FEM) to verify the stresses developed, as well as their intensity and scope, using a color scale generated in a virtual computer analysis environment (Ansys Workbench Software). The results allowed us to observe that different stresses are generated in the material used in the prosthetic infrastructure, depending on its variation. A directly proportional relationship was found between the stiffness of the material and the stresses generated, meaning that greater rigidity results in greater stresses. It is important to highlight that there was no imminent risk of harm to the biomechanics in any varying situation in the infrastructure material, except acrylic resin, which reached stress thresholds in the prosthetic structure close to its maximum flexural resistance.

Journal of Oral ImplantologyVol. 51(3)
Universidade de Ribeirão Preto (BR), Universidade de São Paulo (BR), Universidade de Rio Verde (BR), Universidade Federal de Uberlândia (BR)
Industry, innovation and infrastructure
Openalex Percentile: Top 19%
Dental Implant Techniques and Outcomes
1.79
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.