Experimental and numerical assessment of rainwater intrusion in ventilated facades with open joints

Rainwater ingress is the primary source of premature degradation of building materials. However, currently little quantitative information is available on rain water management of wall systems in general, and ventilated facades in particular: how much water infiltrates, how much water crosses the cavity, and what is the impact on the hygrothermal performance? To understand the water and moisture management of ventilated façades with open joints, experimental watertightness tests were conducted to assess the impact of cavity depth, width of the panel joints, out-of-plane installation of panels, and dimensions of supporting structure. A test setup was designed to quatify the rainwater infiltration in the wall cavity. Subsequently, an experimental study was done on the rainwater infiltration into the insulation layer for different materials (PU and mineral wool), airtightness level, and workmanship (with and without common deficiencies). The results from both test series were then used to simulate the impact of rainwater ingress on the hygrothermal behavior by means numerical simulations. 1D hygrothermal simulations were conducted for ventilated facades located in Brussels (Belgium), Bergen (Norway), and Lisbon (Portugal). The risk for mold problems is small as the drying potential due to the ventilated cavity is large. However, infiltration may have a significant impact on the latent heat transport and annual heat flux. For a cavity of 40 mm the increase in heat flow is limited to 0.4%, whereas for a 20 mm cavity the increase rises to 10.5%. The installation of a WRB reduces the infiltration of water into the insulation, but the effect of installation errors also increases due to reduced drying potential.

Authors

Institutions

Publication Details

Journal
Journal of Building Physics
Published
2025-03-16
DOI
https://doi.org/10.1177/17442591251324122
Citations
2
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
1.60
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and numerical assessment of rainwater intrusion in ventilated facades with open joints

Stéphanie Van Linden, Nathan Van Den Bossche
2 citations
Journal of Building Physics
Wind and Air Flow Studies
1.60
article

Experimental and numerical assessment of rainwater intrusion in ventilated facades with open joints

Stéphanie Van Linden, Nathan Van Den Bossche
article en
2 citations

Abstract

Rainwater ingress is the primary source of premature degradation of building materials. However, currently little quantitative information is available on rain water management of wall systems in general, and ventilated facades in particular: how much water infiltrates, how much water crosses the cavity, and what is the impact on the hygrothermal performance? To understand the water and moisture management of ventilated façades with open joints, experimental watertightness tests were conducted to assess the impact of cavity depth, width of the panel joints, out-of-plane installation of panels, and dimensions of supporting structure. A test setup was designed to quatify the rainwater infiltration in the wall cavity. Subsequently, an experimental study was done on the rainwater infiltration into the insulation layer for different materials (PU and mineral wool), airtightness level, and workmanship (with and without common deficiencies). The results from both test series were then used to simulate the impact of rainwater ingress on the hygrothermal behavior by means numerical simulations. 1D hygrothermal simulations were conducted for ventilated facades located in Brussels (Belgium), Bergen (Norway), and Lisbon (Portugal). The risk for mold problems is small as the drying potential due to the ventilated cavity is large. However, infiltration may have a significant impact on the latent heat transport and annual heat flux. For a cavity of 40 mm the increase in heat flow is limited to 0.4%, whereas for a 20 mm cavity the increase rises to 10.5%. The installation of a WRB reduces the infiltration of water into the insulation, but the effect of installation errors also increases due to reduced drying potential.

Journal of Building PhysicsVol. 49(2)
Ghent University (BE)
Openalex Percentile: Top 20%
Wind and Air Flow Studies
1.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.