<b>Background:</b> Pursuing optimal visual outcomes following cataract surgery remains a cornerstone of modern ophthalmology. Central to this objective is the precise calculation of intraocular lens power. However, despite significant advancements in biometric measurements and computational algorithms, variability in refractive outcomes continues to pose a challenge. This study aims to analyze the outcomes comprehensively by reviewing established and newer techniques. <b>Methods:</b> The eyes included in this study were evaluated based on various criteria, and a total of 210 eyes which met these criteria were included in the research. Our study is a retrospectively designed observational research study. The study included individuals who had experienced successful IOL implantation to correct refractive errors or cataracts. The ARGOS SS-OCT device, a spectral-domain optical coherence tomography system, was used in this study. In measuring the lens power, values were obtained using the Barrett Universal II and Ladas Super Formulas. These values were compared. Postoperative assessments were conducted at 1-3 months and 3-12 months, including spherical equivalents. <b>Results:</b> The mean age of the participants was 63.44 ± 11.62 years. The study's two most frequently used lens brands were ALCON and ZEISS. The lens powers calculated using the Barrett Universal II and Ladas Super Formulas were compared. The mean values calculated using both formulas were highly similar, with no statistically significant differences observed. We compared the spherical equivalent values calculated during the participants' first and second postoperative follow-ups. The spherical equivalent values were similar, with no statistically significant differences. <b>Conclusions:</b> Formulas represent significant advances in ophthalmology and significantly improve visual outcomes; however, differences in their methodology and predictive accuracy warrant further analysis.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-03-17
DOI
https://doi.org/10.3390/jcm14062023
Citations
1
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Traditional and AI-Based Methods: Barrett Universal II vs. Ladas Super Formula in IOL Power Calculation

Mihnea Munteanu, Horia Tudor Stanca, Leila Al Barri, Nadina Mercea et al.
1 citations
Journal of Clinical Medicine
Ophthalmology and Visual Impairment Studies
1.35
article

Comparison of Traditional and AI-Based Methods: Barrett Universal II vs. Ladas Super Formula in IOL Power Calculation

Mihnea Munteanu, Horia Tudor Stanca, Leila Al Barri, Nadina Mercea, Ionela-Iasmina Yasar, Servet Yasar
article en
1 citations

Abstract

<b>Background:</b> Pursuing optimal visual outcomes following cataract surgery remains a cornerstone of modern ophthalmology. Central to this objective is the precise calculation of intraocular lens power. However, despite significant advancements in biometric measurements and computational algorithms, variability in refractive outcomes continues to pose a challenge. This study aims to analyze the outcomes comprehensively by reviewing established and newer techniques. <b>Methods:</b> The eyes included in this study were evaluated based on various criteria, and a total of 210 eyes which met these criteria were included in the research. Our study is a retrospectively designed observational research study. The study included individuals who had experienced successful IOL implantation to correct refractive errors or cataracts. The ARGOS SS-OCT device, a spectral-domain optical coherence tomography system, was used in this study. In measuring the lens power, values were obtained using the Barrett Universal II and Ladas Super Formulas. These values were compared. Postoperative assessments were conducted at 1-3 months and 3-12 months, including spherical equivalents. <b>Results:</b> The mean age of the participants was 63.44 ± 11.62 years. The study's two most frequently used lens brands were ALCON and ZEISS. The lens powers calculated using the Barrett Universal II and Ladas Super Formulas were compared. The mean values calculated using both formulas were highly similar, with no statistically significant differences observed. We compared the spherical equivalent values calculated during the participants' first and second postoperative follow-ups. The spherical equivalent values were similar, with no statistically significant differences. <b>Conclusions:</b> Formulas represent significant advances in ophthalmology and significantly improve visual outcomes; however, differences in their methodology and predictive accuracy warrant further analysis.

Journal of Clinical MedicineVol. 14(6)
Carol Davila University of Medicine and Pharmacy (RO), Victor Babeș University of Medicine and Pharmacy Timișoara (RO)
Openalex Percentile: Top 22%
Ophthalmology and Visual Impairment Studies
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.