High-speed Compressed Air Filtration Device: An Effective Alternative to Decrease Cross-contamination in Dental Care

Aims: To develop and evaluate the effectiveness of a filtration device designed to decrease the microbial load in the air system of the dental chair. Methodology: This experimental, laboratory-based, quantitative study involved the construction of a filtration device using modified high-speed handpieces, rubber gaskets, N95 mask filters, and welding. Sample collection was organized into four groups: Group A - Sterilized distilled water; Group B - High-speed handpiece with a closed water system and the filtration device; Group C - High-speed handpiece with a closed water system without the filtration device; and Group D – The filter from the filtration device after use. Samples were incubated at 37°C for 48 hours, quantified for microbial growth, Gram-stained, and analyzed microscopically. Data were analyzed using SPSS Statistics 25®, with nonparametric tests applied (Kruskal-Wallis and Dunn’s post hoc test) due to the non-normal data distribution (Shapiro-Wilk test, P < 0.05). Results: No microbial growth was observed in Group A, confirming the sterility of the water. Group B, exhibited an average of 3.33±3.50 colony-forming units (CFU), representing a significant reduction (p<0.05) compared to Group C, which showed substantially higher contamination (32.11±188.36 CFU). The filter in Group D retained microorganisms, with an average growth of 3.00±6.00 CFU, confirming its role in microbial filtration. Conclusion: The filtration device effectively reduced the microbial load in the dental chair's air system, demonstrating its effectiveness as a biosafety measure to minimize cross-contamination in dental environments. Its implementation can contribute to improving infection control, enhancing safety for both professionals and patients.

Authors

Institutions

Publication Details

Journal
Journal of Advances in Medicine and Medical Research
Published
2025-03-17
DOI
https://doi.org/10.9734/jammr/2025/v37i45777
Primary Topic
Dental Research and COVID-19
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-speed Compressed Air Filtration Device: An Effective Alternative to Decrease Cross-contamination in Dental Care

Ana Lúcia Roselino Ribeiro, Fernanda Fresneda Villibor, Túlio Silva Rosa, E. B. de Oliveira et al.
Journal of Advances in Medicine and Medical Research
Dental Research and COVID-19
article

High-speed Compressed Air Filtration Device: An Effective Alternative to Decrease Cross-contamination in Dental Care

Ana Lúcia Roselino Ribeiro, Fernanda Fresneda Villibor, Túlio Silva Rosa, E. B. de Oliveira, Iangla Araújo de Melo Damasceno, João Azevedo, Alan Alves Machado, Nicole Lonni
article en

Abstract

Aims: To develop and evaluate the effectiveness of a filtration device designed to decrease the microbial load in the air system of the dental chair. Methodology: This experimental, laboratory-based, quantitative study involved the construction of a filtration device using modified high-speed handpieces, rubber gaskets, N95 mask filters, and welding. Sample collection was organized into four groups: Group A - Sterilized distilled water; Group B - High-speed handpiece with a closed water system and the filtration device; Group C - High-speed handpiece with a closed water system without the filtration device; and Group D – The filter from the filtration device after use. Samples were incubated at 37°C for 48 hours, quantified for microbial growth, Gram-stained, and analyzed microscopically. Data were analyzed using SPSS Statistics 25®, with nonparametric tests applied (Kruskal-Wallis and Dunn’s post hoc test) due to the non-normal data distribution (Shapiro-Wilk test, P < 0.05). Results: No microbial growth was observed in Group A, confirming the sterility of the water. Group B, exhibited an average of 3.33±3.50 colony-forming units (CFU), representing a significant reduction (p<0.05) compared to Group C, which showed substantially higher contamination (32.11±188.36 CFU). The filter in Group D retained microorganisms, with an average growth of 3.00±6.00 CFU, confirming its role in microbial filtration. Conclusion: The filtration device effectively reduced the microbial load in the dental chair's air system, demonstrating its effectiveness as a biosafety measure to minimize cross-contamination in dental environments. Its implementation can contribute to improving infection control, enhancing safety for both professionals and patients.

Journal of Advances in Medicine and Medical ResearchVol. 37(4)
Universidade Federal de Santa Catarina (BR)
Openalex Percentile: Top 91%
Dental Research and COVID-19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.