A Physics‐Data Driven Approach for Identifying Leakage Users in Low‐Voltage Distribution Systems

ABSTRACT Wiring errors, caused by improper connections between neutral lines and protective earth (PE) lines due to negligence by electrical technicians, are a prevalent type of earth fault in low‐voltage distribution systems (LVDS). These errors can cause the load current of affected users to flow back to the transformer's neutral point via the PE line as residual current, leading to nuisance tripping of residual current devices (RCDs). To maintain normal power supply, users may disable RCDs, which compromises safety and can result in severe hazards such as electric shocks and electrical fires. This paper proposes a method to locate users with wiring errors by leveraging abundant metering data within LVDS and utilising leakage fault analysis devices. We construct a linear model of residual current considering multiple error scenarios. Based on this model, a multiple linear regression (MLR) approach is developed to identify and locate anomalous users by analysing the correlation between their load currents and the residual current of the LVDS. Experimental results under various scenarios validate the performance of the proposed method.

Authors

Institutions

Publication Details

Journal
IET Generation Transmission & Distribution
Published
2025-01-01
DOI
https://doi.org/10.1049/gtd2.70040
Primary Topic
Electricity Theft Detection Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Physics‐Data Driven Approach for Identifying Leakage Users in Low‐Voltage Distribution Systems

Hao Xiao, Bin Li, Peijun Zhong, Sheng Su et al.
IET Generation Transmission & Distribution
Electricity Theft Detection Techniques
article

A Physics‐Data Driven Approach for Identifying Leakage Users in Low‐Voltage Distribution Systems

Hao Xiao, Bin Li, Peijun Zhong, Sheng Su, Xiaofei Feng
article en

Abstract

ABSTRACT Wiring errors, caused by improper connections between neutral lines and protective earth (PE) lines due to negligence by electrical technicians, are a prevalent type of earth fault in low‐voltage distribution systems (LVDS). These errors can cause the load current of affected users to flow back to the transformer's neutral point via the PE line as residual current, leading to nuisance tripping of residual current devices (RCDs). To maintain normal power supply, users may disable RCDs, which compromises safety and can result in severe hazards such as electric shocks and electrical fires. This paper proposes a method to locate users with wiring errors by leveraging abundant metering data within LVDS and utilising leakage fault analysis devices. We construct a linear model of residual current considering multiple error scenarios. Based on this model, a multiple linear regression (MLR) approach is developed to identify and locate anomalous users by analysing the correlation between their load currents and the residual current of the LVDS. Experimental results under various scenarios validate the performance of the proposed method.

IET Generation Transmission & DistributionVol. 19(1)
University of Manitoba (CA), Changsha University of Science and Technology (CN)
Openalex Percentile: Top 96%
Electricity Theft Detection Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.