LOCAL TISSUE DOSES IN A MISSION BEYOND EARTH’S MAGNETOSPHERE BEHIND VARIOUS SPACECRAFT SHIELDING WITH CONSIDERATION OF THE DECREASES OF PROTONS AND HELIUM IONS EFFECTIVENESS

The paper presents the contemporary view of the risks from space radiation, retrospective of dose limits regulation, total risk estimation and plausible lifespan reduction in consequence of extended orbital and exploration missions. The authors analyze the potential of thickening the aluminum-polyethylene shielding to reduce doses from galactic space radiation (GSR) in space exploration missions. For this purpose, dose calculation was performed with consideration of the times reduction of the effectiveness of protons and GSR helium ions with low dose rate owing to a rapid reparation of cells in radiation-sensitive tissues. It was shown that dependence the new quality factor (QF) on linear energy transfer (LET) to tissues and reduction of the protons and helium ions effectiveness in comparison to the existing calculational techniques reduces 2-3 folds the annual local tissue equivalent doses behind a 30–100 g/cm2 aluminum shield and 3-4 folds behind polyethylene. With the new QF -LET dependence, the multiple dose reduction due to buildingup of the shielding thickness compensates the double dose growth behind thin shielding.

Authors

Publication Details

Journal
Aerospace and Environmental Medicine
Published
2025-01-01
DOI
https://doi.org/10.21687/0233-528x-2025-59-1-44-54
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LOCAL TISSUE DOSES IN A MISSION BEYOND EARTH’S MAGNETOSPHERE BEHIND VARIOUS SPACECRAFT SHIELDING WITH CONSIDERATION OF THE DECREASES OF PROTONS AND HELIUM IONS EFFECTIVENESS

Vyacheslav Shurshakov, Victor Benghin, A.V. Shafirkin
Aerospace and Environmental Medicine
Radiation Therapy and Dosimetry
article

LOCAL TISSUE DOSES IN A MISSION BEYOND EARTH’S MAGNETOSPHERE BEHIND VARIOUS SPACECRAFT SHIELDING WITH CONSIDERATION OF THE DECREASES OF PROTONS AND HELIUM IONS EFFECTIVENESS

Vyacheslav Shurshakov, Victor Benghin, A.V. Shafirkin
article en

Abstract

The paper presents the contemporary view of the risks from space radiation, retrospective of dose limits regulation, total risk estimation and plausible lifespan reduction in consequence of extended orbital and exploration missions. The authors analyze the potential of thickening the aluminum-polyethylene shielding to reduce doses from galactic space radiation (GSR) in space exploration missions. For this purpose, dose calculation was performed with consideration of the times reduction of the effectiveness of protons and GSR helium ions with low dose rate owing to a rapid reparation of cells in radiation-sensitive tissues. It was shown that dependence the new quality factor (QF) on linear energy transfer (LET) to tissues and reduction of the protons and helium ions effectiveness in comparison to the existing calculational techniques reduces 2-3 folds the annual local tissue equivalent doses behind a 30–100 g/cm2 aluminum shield and 3-4 folds behind polyethylene. With the new QF -LET dependence, the multiple dose reduction due to buildingup of the shielding thickness compensates the double dose growth behind thin shielding.

Aerospace and Environmental MedicineVol. 59(1)
Openalex Percentile: Top 93%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.