Analysis of Indoor PM2.5 Contaminants Based on Outdoor Wind Velocity Through Different Infiltration Types

Nowadays, indoor PM2.5 concentrations have become a significant factor affecting indoor air quality (IAQ) and a major public concern, particularly with the rise of haze in Thailand and globally, as PM2.5 can penetrate human lungs. This research analyzes the dispersion of PM2.5 from outdoors to indoors using a fluid dynamics simulation framework that combines the Eulerian approach for continuous flow, the Lagrangian approach for particulate matter dispersion, and the RNG k‐ ε turbulent model for airflow. The study is aimed at protecting indoor environments from harmful exposure to PM2.5 from outdoor contaminants and improving IAQ. Primarily, three different infiltration types and shapes are studied to determine the minimum optimal positive room pressure, based on the impact of ambient wind velocity on indoor PM2.5 concentrations from outdoor pollutants. A minimum optimal pressure of 3.6 Pa and 27 air changes per hour (ACH) is sufficient to achieve a PM2.5‐free indoor environment for all infiltration models. Furthermore, higher wind speeds can reduce indoor PM2.5 concentrations due to the increased momentum of particles. This research technique is implemented in the practical field study conducted within the laboratory room of the 55‐Year Chalermprakiat Building. As a result, the investigated room, with an infiltration area of 0.06 m 2 and a rate of 0.0036 m 3 /s, will be certified as a clean room by achieving an optimal minimum pressure of approximately 0.01 Pa. This research will help achieve cleaner and safer indoor environments for any building by leveraging the optimal minimum pressure of cleanroom technology, provided that the infiltration rate and ambient wind velocity are accurately determined.

Authors

Institutions

Publication Details

Journal
Journal of Engineering
Published
2025-01-01
DOI
https://doi.org/10.1155/je/4145524
Primary Topic
Air Quality and Health Impacts
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Indoor PM2.5 Contaminants Based on Outdoor Wind Velocity Through Different Infiltration Types

Mongkol Mongkolwongrojn, Komsilp Kotmool, Ghaim Man Oo
Journal of Engineering
Air Quality and Health Impacts
article

Analysis of Indoor PM2.5 Contaminants Based on Outdoor Wind Velocity Through Different Infiltration Types

Mongkol Mongkolwongrojn, Komsilp Kotmool, Ghaim Man Oo
article en

Abstract

Nowadays, indoor PM2.5 concentrations have become a significant factor affecting indoor air quality (IAQ) and a major public concern, particularly with the rise of haze in Thailand and globally, as PM2.5 can penetrate human lungs. This research analyzes the dispersion of PM2.5 from outdoors to indoors using a fluid dynamics simulation framework that combines the Eulerian approach for continuous flow, the Lagrangian approach for particulate matter dispersion, and the RNG k‐ ε turbulent model for airflow. The study is aimed at protecting indoor environments from harmful exposure to PM2.5 from outdoor contaminants and improving IAQ. Primarily, three different infiltration types and shapes are studied to determine the minimum optimal positive room pressure, based on the impact of ambient wind velocity on indoor PM2.5 concentrations from outdoor pollutants. A minimum optimal pressure of 3.6 Pa and 27 air changes per hour (ACH) is sufficient to achieve a PM2.5‐free indoor environment for all infiltration models. Furthermore, higher wind speeds can reduce indoor PM2.5 concentrations due to the increased momentum of particles. This research technique is implemented in the practical field study conducted within the laboratory room of the 55‐Year Chalermprakiat Building. As a result, the investigated room, with an infiltration area of 0.06 m 2 and a rate of 0.0036 m 3 /s, will be certified as a clean room by achieving an optimal minimum pressure of approximately 0.01 Pa. This research will help achieve cleaner and safer indoor environments for any building by leveraging the optimal minimum pressure of cleanroom technology, provided that the infiltration rate and ambient wind velocity are accurately determined.

Journal of EngineeringVol. 2025(1)
King Mongkut's Institute of Technology Ladkrabang (TH)
King Mongkut's Institute of Technology Ladkrabang
Openalex Percentile: Top 94%
Air Quality and Health Impacts
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Indoor PM2.5 Contaminants Based on Outdoor Wind Velocity Through Different Infiltration Types — Mongkol Mongkolwongrojn, Komsilp Kotmool, et al. · Journal of Engineering (2025) | TGRS Research Map | TGRS