Numerical Evaluation of the Equivalent Damping Ratio Due to Dissipative Roof Structure in the Retrofit of Historical Churches

This paper is focused on the numerical evaluation of the equivalent damping ratio (EDR) given by a dissipative wood-based roof diaphragm in the seismic retrofitting of single-nave historical churches. In the design phase, the EDR could be a key parameter to select the optimal roof structure configuration, thereby obtaining the maximum energy dissipation. In this way, the roof structure works as a damper to facilitate a box behavior of the structure during the seismic response. The EDR measures the energy dissipated by the nonlinear behavior of the roof’s steel connections and masonry walls during seismic events. In a preliminary retrofitting design phase, an initial implementation of the geometries of the walls and the chosen geometry for the roof is carried out by adopting an equivalent frame model (FEM) with inelastic rotational hinges for the nonlinear properties of the masonry walls and inelastic shear hinges for the nonlinear behavior of the roof’s steel connections. Since, for historical churches, the transversal response under seismic events is the worst situation for the single-nave configuration, the earthquake is applied as transversal accelerograms. In this way, the damped rocking of the perimeter walls due to the dissipative roof diaphragm can be described in terms of a hysteretic variable. By varying the value of the hysteretic variable, possible configurations of the roof diaphragm are tested in the design phase, considering the different shear deformation values of the inelastic hinges of the roof. Under these hypotheses, the EDR is evaluated by performing nonlinear Time History analyses based on the cyclic behavior of the inelastic hinges of the roof, the strain energy contribution due to the walls, and the lateral displacements of the structure. The EDR values obtained with the Time History method are compared with those obtained by applying the Capacity Spectrum Method by performing nonlinear static analyses, either for the coefficient method of FEMA 356 or the equivalent linearization technique of ATC-40. The EDR evaluations are performed by considering the following different hysteretic behaviors of the roof’s steel connections: the skeleton curves with stiffness degradation and the trilinear model with strength and stiffness degradation. Finally, the variation in the EDR values as a function of the hysteretic variable is presented as well so to evaluate if the maximum EDR value corresponds to the optimal value of the hysteretic variable able to reduce the lateral displacements and to contain the shear forces acting on the roof and the façade under a safety limit.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-03-17
DOI
https://doi.org/10.3390/app15063286
Citations
2
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
1.91
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Evaluation of the Equivalent Damping Ratio Due to Dissipative Roof Structure in the Retrofit of Historical Churches

Marco Zucca, Manuela Alessandra Scamardo, Nicola Longarini, Pietro Giuseppe Crespi
2 citations
Applied Sciences
Masonry and Concrete Structural Analysis
1.91
article

Numerical Evaluation of the Equivalent Damping Ratio Due to Dissipative Roof Structure in the Retrofit of Historical Churches

Marco Zucca, Manuela Alessandra Scamardo, Nicola Longarini, Pietro Giuseppe Crespi
article en
2 citations

Abstract

This paper is focused on the numerical evaluation of the equivalent damping ratio (EDR) given by a dissipative wood-based roof diaphragm in the seismic retrofitting of single-nave historical churches. In the design phase, the EDR could be a key parameter to select the optimal roof structure configuration, thereby obtaining the maximum energy dissipation. In this way, the roof structure works as a damper to facilitate a box behavior of the structure during the seismic response. The EDR measures the energy dissipated by the nonlinear behavior of the roof’s steel connections and masonry walls during seismic events. In a preliminary retrofitting design phase, an initial implementation of the geometries of the walls and the chosen geometry for the roof is carried out by adopting an equivalent frame model (FEM) with inelastic rotational hinges for the nonlinear properties of the masonry walls and inelastic shear hinges for the nonlinear behavior of the roof’s steel connections. Since, for historical churches, the transversal response under seismic events is the worst situation for the single-nave configuration, the earthquake is applied as transversal accelerograms. In this way, the damped rocking of the perimeter walls due to the dissipative roof diaphragm can be described in terms of a hysteretic variable. By varying the value of the hysteretic variable, possible configurations of the roof diaphragm are tested in the design phase, considering the different shear deformation values of the inelastic hinges of the roof. Under these hypotheses, the EDR is evaluated by performing nonlinear Time History analyses based on the cyclic behavior of the inelastic hinges of the roof, the strain energy contribution due to the walls, and the lateral displacements of the structure. The EDR values obtained with the Time History method are compared with those obtained by applying the Capacity Spectrum Method by performing nonlinear static analyses, either for the coefficient method of FEMA 356 or the equivalent linearization technique of ATC-40. The EDR evaluations are performed by considering the following different hysteretic behaviors of the roof’s steel connections: the skeleton curves with stiffness degradation and the trilinear model with strength and stiffness degradation. Finally, the variation in the EDR values as a function of the hysteretic variable is presented as well so to evaluate if the maximum EDR value corresponds to the optimal value of the hysteretic variable able to reduce the lateral displacements and to contain the shear forces acting on the roof and the façade under a safety limit.

Applied SciencesVol. 15(6)
University of Cagliari (IT), Politecnico di Milano (IT)
Openalex Percentile: Top 17%
Masonry and Concrete Structural Analysis
1.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.