On the Application of Oxynitride Thin Films in Biomedicine

The structure, morphology, and roughness of Ti–O–N coatings applied to stainless steel surfaces using reactive magnetron sputtering are investigated for use as biomedical stents. The deposition modes are analyzed with a negative bias applied to the substrate (–60 V), with no bias applied to the substrate, and with varying nitrogen-to-oxygen ratios in the working gas. The resulting coatings exhibited an anatase structure. Analysis by scanning electron microscopy shows a decrease in the grain size of the films with an increase in nitrogen concentration in the working gas when a negative bias (–60 V) is simultaneously applied. In vitro studies conducted on blood donors, involving blood collection followed by plasma separation from erythrocytes through centrifugation at a rate of 1–2 mL/min, demonstrate that the use of Ti–O–N-coated substrates (–60 V) decrease platelet levels and increase hematocrit values.

Authors

Institutions

Publication Details

Journal
Journal of Surface Investigation X-ray Synchrotron and Neutron Techniques
Published
2024-12-01
DOI
https://doi.org/10.1134/s1027451024702008
Primary Topic
Anesthesia and Neurotoxicity Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the Application of Oxynitride Thin Films in Biomedicine

Elena Lisichko, В. С. Сыпченко, Н. Н. Никитенков, V. S. Filimonova et al.
Journal of Surface Investigation X-ray Synchrotron and Neutron Techniques
Anesthesia and Neurotoxicity Research
article

On the Application of Oxynitride Thin Films in Biomedicine

Elena Lisichko, В. С. Сыпченко, Н. Н. Никитенков, V. S. Filimonova, S. Y. Karelin, L. A. Krasnobaeva, S. V. Gusakova
article en

Abstract

The structure, morphology, and roughness of Ti–O–N coatings applied to stainless steel surfaces using reactive magnetron sputtering are investigated for use as biomedical stents. The deposition modes are analyzed with a negative bias applied to the substrate (–60 V), with no bias applied to the substrate, and with varying nitrogen-to-oxygen ratios in the working gas. The resulting coatings exhibited an anatase structure. Analysis by scanning electron microscopy shows a decrease in the grain size of the films with an increase in nitrogen concentration in the working gas when a negative bias (–60 V) is simultaneously applied. In vitro studies conducted on blood donors, involving blood collection followed by plasma separation from erythrocytes through centrifugation at a rate of 1–2 mL/min, demonstrate that the use of Ti–O–N-coated substrates (–60 V) decrease platelet levels and increase hematocrit values.

Journal of Surface Investigation X-ray Synchrotron and Neutron TechniquesVol. 18(S1)
National Research Tomsk State University (RU), Siberian State Medical University (RU), Tomsk Polytechnic University (RU)
Openalex Percentile: Top 71%
Anesthesia and Neurotoxicity Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.