Study on partial discharge of transformer based on wide frequency equivalent circuit

When partial discharge occurs in the transformer, it will produce higher frequency pulse current, high frequency phenomenon will enhance the circuit capacitance effect, making the circuit bandwidth, in order to detect the local discharge signal so as to realize the transformer for equipment monitoring, the establishment of the transformer broadband equivalent circuit model, the propagation law of partial discharge pulse current signal in the transformer is investigated, and the effects of four denoising methods are compared under different evaluation indexes; finally, a typical transformer partial discharge condition is studied, and the validity of the transformer partial discharge research based on the wide-band equivalent circuit is verified.

Authors

Institutions

Publication Details

Published
2024-11-01
DOI
https://doi.org/10.1109/icei63732.2024.10917248
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on partial discharge of transformer based on wide frequency equivalent circuit

Ka Mu, Jianning Chen, Chang‐Ming Jiang, Huan Li et al.
Advanced Sensor and Control Systems
article

Study on partial discharge of transformer based on wide frequency equivalent circuit

Ka Mu, Jianning Chen, Chang‐Ming Jiang, Huan Li, Ping Li, Yuanxiang Zhou, Yunpeng Tang, Zhiyang He
article en

Abstract

When partial discharge occurs in the transformer, it will produce higher frequency pulse current, high frequency phenomenon will enhance the circuit capacitance effect, making the circuit bandwidth, in order to detect the local discharge signal so as to realize the transformer for equipment monitoring, the establishment of the transformer broadband equivalent circuit model, the propagation law of partial discharge pulse current signal in the transformer is investigated, and the effects of four denoising methods are compared under different evaluation indexes; finally, a typical transformer partial discharge condition is studied, and the validity of the transformer partial discharge research based on the wide-band equivalent circuit is verified.

State Grid Corporation of China (China) (CN), Tsinghua University (CN)
State Grid Corporation of China
Affordable and clean energy
Openalex Percentile: Top 65%
Advanced Sensor and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.