Spatial Resolution of Low-Density OPM-MEG: A Comparative Analysis With High-Density EEG

Electroencephalography (EEG) and magnetoencephalography (MEG) are noninvasive neuroimaging techniques used to detect and localize brain activity. Unlike cumbersome MEG systems that employ superconducting quantum interference devices (SQUIDs), EEG and the emerging optically pumped magnetometer-based MEG (OPM-MEG) systems are wearable and compact, allowing subjects to move naturally during data acquisition. With limited sensor numbers, OPM sensors can be locally arranged for the brain area of interest to enhance the spatial resolution. In this study, we aimed to investigate the spatial resolution of low-density OPM-MEG with locally arranged sensor arrays by comparing it with high-density EEG, providing insights into its practical application. Simulations of three 32-channel local arrays targeting functional brain regions were compared to those obtained via a 128-channel EEG by using the resolution matrix as an indicator. To align with real-world scenarios, we further investigated the mechanism by which skull conductivity and co-registration errors affect source localization accuracy. We conducted median nerve stimulation (MNS) experiments using both the constructed OPM-MEG and EEG to validate their source localization performance. The simulation results demonstrated that OPM-MEG provides spatial specificity comparable to or even exceeding EEG. In real-world experiments, both modalities achieved accurate localizations, with similar source distributions. Simulations and experiments confirmed the comparable spatial localization performance of both systems, highlighting the potential of low-density OPM-MEG for research on a specific brain function. Low-density OPM-MEG presents a promising alternative to high-density EEG, potentially improving accuracy, and participant comfort.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3551466
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spatial Resolution of Low-Density OPM-MEG: A Comparative Analysis With High-Density EEG

Fuzhi Cao, Jianzhi Yang, Zhenfeng Gao, Wen Li et al.
IEEE Transactions on Instrumentation and Measurement
Optical Imaging and Spectroscopy Techniques
article

Spatial Resolution of Low-Density OPM-MEG: A Comparative Analysis With High-Density EEG

Fuzhi Cao, Jianzhi Yang, Zhenfeng Gao, Wen Li, Dawei Wang, Wenli Wang, Nan An
article en

Abstract

Electroencephalography (EEG) and magnetoencephalography (MEG) are noninvasive neuroimaging techniques used to detect and localize brain activity. Unlike cumbersome MEG systems that employ superconducting quantum interference devices (SQUIDs), EEG and the emerging optically pumped magnetometer-based MEG (OPM-MEG) systems are wearable and compact, allowing subjects to move naturally during data acquisition. With limited sensor numbers, OPM sensors can be locally arranged for the brain area of interest to enhance the spatial resolution. In this study, we aimed to investigate the spatial resolution of low-density OPM-MEG with locally arranged sensor arrays by comparing it with high-density EEG, providing insights into its practical application. Simulations of three 32-channel local arrays targeting functional brain regions were compared to those obtained via a 128-channel EEG by using the resolution matrix as an indicator. To align with real-world scenarios, we further investigated the mechanism by which skull conductivity and co-registration errors affect source localization accuracy. We conducted median nerve stimulation (MNS) experiments using both the constructed OPM-MEG and EEG to validate their source localization performance. The simulation results demonstrated that OPM-MEG provides spatial specificity comparable to or even exceeding EEG. In real-world experiments, both modalities achieved accurate localizations, with similar source distributions. Simulations and experiments confirmed the comparable spatial localization performance of both systems, highlighting the potential of low-density OPM-MEG for research on a specific brain function. Low-density OPM-MEG presents a promising alternative to high-density EEG, potentially improving accuracy, and participant comfort.

IEEE Transactions on Instrumentation and MeasurementVol. 74
National High Magnetic Field Laboratory (US), Qilu Hospital of Shandong University (CN), Beihang University (CN)
National Natural Science Foundation of China, China Postdoctoral Science Foundation, Natural Science Foundation of Shandong Province, Key Technology Research and Development Program of Shandong, National Postdoctoral Program for Innovative Talents
Openalex Percentile: Top 93%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.