Voxel-Sensitive Attention-Based Lattice Structure Residual Network for Low-Dose CT Image Denoising Using Wavelet-Based Structure Loss
Low-dose computed tomography (LDCT) imaging safeguards patients from potentially harmful X-rays. However, the signal-to-noise ratio (SNR) and computed tomography (CT) image quality deteriorate due to lower X-ray flux in the LDCT imaging modality. The custom design of deep networks with vanilla convolution layers ignores sensitive voxel information. Hence, voxel details for reconstructing low-contrast regions and high-frequency lesion edges may be lost during noise suppression. In addition, existing techniques do not satisfactorily address the problem of adversarial learning-induced structural deformation. This article proposes a LDCT denoising method based on Wasserstein GAN (WGAN) with three novel contributions. First, we introduce a novel build block called a voxel-sensitive attention-based lattice residual block (VSA-LRB). The generator network with stacked VSA-LRB can preserve the long-range pixel dependency while aggregating the voxel-sensitive features extracted along the spatial (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$H \times W$ </tex-math></inline-formula>) and depthwise (D) directions. Furthermore, we train the proposed denoising network to learn efficient structural features via our proposed wavelet-based structural loss. The error is estimated on the wavelet-domain structural feature space, extracted by a dedicated pretrained CT-specific structure-aware network (CT-SANet). Hence, the wavelet-based loss function effectively mitigates structural distortions. We introduce a differential content loss to improve high-frequency lesion boundaries. The proposed method is validated qualitatively and quantitatively using two publicly available datasets: the “2016 NIH-AAPM-Mayo Clinic LDCT Grand Challenge dataset” and the “Low-dose-CT Image and Projection dataset.” The proposed method demonstrates a superior performance when compared with state-of-the-art techniques.
Authors
- Naragoni Saidulu (ORCID: https://orcid.org/0009-0004-6884-4960)
- Priya Ranjan Muduli (ORCID: https://orcid.org/0000-0002-9276-8361)
- Vinit Kumar (ORCID: https://orcid.org/0000-0003-2779-1095)
Institutions
- Indian Institute of Technology BHU (IN)
- Banaras Hindu University (IN)
Publication Details
- Journal
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1109/tim.2025.3551793
- Citations
- 2
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 2.72