Safe Start Regions for Medical Steerable Needle Automation

Steerable needles are minimally invasive devices that enable novel medical procedures by following curved paths to avoid critical anatomical obstacles. We introduce a new start pose robustness metric for steerable needle motion plans. A steerable needle deployment typically consists of a physician manually placing a steerable needle at a precomputed start pose on the surface of tissue and handing off control to a robot, which then autonomously steers the needle through the tissue to the target. The handoff between humans and robots is critical for procedure success, as even small deviations from a planned start pose change the steerable needle's reachable workspace. Our metric is based on a novel geometric method to efficiently compute how far the physician can deviate from the planned start pose in both position and orientation such that the steerable needle can still reach the target. We evaluate our metric through simulation in liver and lung scenarios. Our evaluation shows that our metric can be applied to plans computed by different steerable needle motion planners and that it can be used to efficiently select plans with large safe start regions.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Robotics
Published
2025-01-01
DOI
https://doi.org/10.1109/tro.2025.3552323
Citations
3
Primary Topic
Quality and Safety in Healthcare
Type
article
Field-Weighted Citation Impact
10.59
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Safe Start Regions for Medical Steerable Needle Automation

Robert J. Webster, Inbar Fried, Ron Alterovitz, Jason Akulian et al.
3 citations
IEEE Transactions on Robotics
Quality and Safety in Healthcare
10.59
article

Safe Start Regions for Medical Steerable Needle Automation

Robert J. Webster, Inbar Fried, Ron Alterovitz, Jason Akulian, Janine Hoelscher, Spiros Tsalikis
article en
3 citations

Abstract

Steerable needles are minimally invasive devices that enable novel medical procedures by following curved paths to avoid critical anatomical obstacles. We introduce a new start pose robustness metric for steerable needle motion plans. A steerable needle deployment typically consists of a physician manually placing a steerable needle at a precomputed start pose on the surface of tissue and handing off control to a robot, which then autonomously steers the needle through the tissue to the target. The handoff between humans and robots is critical for procedure success, as even small deviations from a planned start pose change the steerable needle's reachable workspace. Our metric is based on a novel geometric method to efficiently compute how far the physician can deviate from the planned start pose in both position and orientation such that the steerable needle can still reach the target. We evaluate our metric through simulation in liver and lung scenarios. Our evaluation shows that our metric can be applied to plans computed by different steerable needle motion planners and that it can be used to efficiently select plans with large safe start regions.

IEEE Transactions on RoboticsVol. 41
University of North Carolina at Chapel Hill (US), Vanderbilt University (US), Clemson University (US)
Openalex Percentile: Top 2%
Quality and Safety in Healthcare
10.59
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Safe Start Regions for Medical Steerable Needle Automation — Robert J. Webster, Inbar Fried, et al. · IEEE Transactions on Robotics (2025) | TGRS Research Map | TGRS