Chest wall strapping in a porcine model: A model for the physiology of the oversized lung allograft

Restrictive lung disease (RLD) is the leading indication for lung transplantation. Donor-to-recipient size matching is challenging in RLD, especially oversizing. Chest-Wall-Strapping (CWS) is a technique forcing the lung to operate at lower volumes. We developed a porcine model of CWS to investigate limits of oversizing. Farm-raised pigs were intubated and mechanically ventilated. Computer tomography (CT) volumetry demonstrated that Total Lung Volume (TLV) at 25 cm H<sub>2</sub>O end-expiratory pressure was 1,204 ml at baseline. Application of increasing doses of CWS reduced TLV to 879 ml (CWS-cuff inflated to 35 mm Hg) and reduced TLV to 620 ml (CWS-cuff inflated to 50 mm Hg). At 50 mm Hg of CWS (50% TLV reduction) atelectasis of the lung bases was evident. Lung elastance was increased with CWS. CT lung-density at 35 mm Hg CWS (30% reduction in TLV) was normal for the inflation state of the lung. Physiological limits of oversizing should be considered for optimal lung function.

Authors

Institutions

Publication Details

Journal
JHLT Open
Published
2025-03-17
DOI
https://doi.org/10.1016/j.jhlto.2025.100248
Citations
4
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
2.70

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Chest wall strapping in a porcine model: A model for the physiology of the oversized lung allograft

Eric Abston, Michael Eberlein
4 citations
JHLT Open
Mechanical Circulatory Support Devices
2.70
article

Chest wall strapping in a porcine model: A model for the physiology of the oversized lung allograft

Eric Abston, Michael Eberlein
article en
4 citations

Abstract

Restrictive lung disease (RLD) is the leading indication for lung transplantation. Donor-to-recipient size matching is challenging in RLD, especially oversizing. Chest-Wall-Strapping (CWS) is a technique forcing the lung to operate at lower volumes. We developed a porcine model of CWS to investigate limits of oversizing. Farm-raised pigs were intubated and mechanically ventilated. Computer tomography (CT) volumetry demonstrated that Total Lung Volume (TLV) at 25 cm H<sub>2</sub>O end-expiratory pressure was 1,204 ml at baseline. Application of increasing doses of CWS reduced TLV to 879 ml (CWS-cuff inflated to 35 mm Hg) and reduced TLV to 620 ml (CWS-cuff inflated to 50 mm Hg). At 50 mm Hg of CWS (50% TLV reduction) atelectasis of the lung bases was evident. Lung elastance was increased with CWS. CT lung-density at 35 mm Hg CWS (30% reduction in TLV) was normal for the inflation state of the lung. Physiological limits of oversizing should be considered for optimal lung function.

JHLT OpenVol. 8
University of Wisconsin–Madison (US), Massachusetts General Hospital (US)
National Center for Advancing Translational Sciences
Openalex Percentile: Top 11%
Mechanical Circulatory Support Devices
2.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.