1D interferometric Mie scattering for micronozzle exit flow velocity measurement

Abstract The non-invasive nature of optical diagnostic techniques is advantageous in studying micronozzles, as it safeguards the undisturbed nature of the highly sensitive micro-scale flow field. In this work, a laser-based interferometric Mie scattering system is developed using a virtually imaged phased array to quantitatively measure the one-dimensional velocity profile at the exit of micronozzles. A narrow-linewidth solid-state laser is used as the light source, acetone-seeded air flow is used as the gas, and velocity is estimated from the Doppler shift in light scattered from the flow exiting the micronozzle. The measurement system is demonstrated on a 2D micronozzle with a 500 mm throat width and a 1 mm exit width. These results are compared with measurements obtained using particle image velocimetry. Peak axial velocities ranging from 370 m s −1 to 450 m s −1 are measured with a precision of approximately 1% and an accuracy of 5%. This system is relatively inexpensive and is particularly suited to micronozzles where the probed region is small in size.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2025-03-17
DOI
https://doi.org/10.1088/1361-6501/adc149
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

1D interferometric Mie scattering for micronozzle exit flow velocity measurement

Aravind Vaidyanathan, Shine Sr, Manu K. Sukesan, Anbarasan Sekar et al.
Measurement Science and Technology
Advanced Sensor Technologies Research
article

1D interferometric Mie scattering for micronozzle exit flow velocity measurement

Aravind Vaidyanathan, Shine Sr, Manu K. Sukesan, Anbarasan Sekar, Yedhu Krishna
article en

Abstract

Abstract The non-invasive nature of optical diagnostic techniques is advantageous in studying micronozzles, as it safeguards the undisturbed nature of the highly sensitive micro-scale flow field. In this work, a laser-based interferometric Mie scattering system is developed using a virtually imaged phased array to quantitatively measure the one-dimensional velocity profile at the exit of micronozzles. A narrow-linewidth solid-state laser is used as the light source, acetone-seeded air flow is used as the gas, and velocity is estimated from the Doppler shift in light scattered from the flow exiting the micronozzle. The measurement system is demonstrated on a 2D micronozzle with a 500 mm throat width and a 1 mm exit width. These results are compared with measurements obtained using particle image velocimetry. Peak axial velocities ranging from 370 m s −1 to 450 m s −1 are measured with a precision of approximately 1% and an accuracy of 5%. This system is relatively inexpensive and is particularly suited to micronozzles where the probed region is small in size.

Measurement Science and TechnologyVol. 36(4)
Indian Institute of Space Science and Technology (IN)
Openalex Percentile: Top 95%
Advanced Sensor Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

1D interferometric Mie scattering for micronozzle exit flow velocity measurement — Aravind Vaidyanathan, Shine Sr, et al. · Measurement Science and Technology (2025) | TGRS Research Map | TGRS