DEVELOPMENT AND VALIDATION OF AN LC-MS/MS METHOD FOR NITROSAMINE IMPURITY DETECTION IN TAMSULOSIN HYDROCHLORIDE

Objective: Regulatory oversight of pharmaceuticals containing nitrosamine contaminants has intensified in the past few years. Unites States Food and Drug Administration (USFDA), European Medicines Agency (EMA) and other regulatory agencies has been quite proactive in sending out warnings, instructions, and safety messages. This study presents a fast, accurate, and selective way to detect and quantify nitrosamine contaminants in Tamsulosin HCl. Methods: The purification of Tamsulosin using Di Methyl Formamide (DMF) requires monitoring to avoid nitrosamine formation. A 150 × 4.6 mm Symmetry® C18 column (5 µm, 40±1 °C) was used with a mobile phase involving water (98%), acetonitrile (2%) with 0.1% formic acid, where flow velocity was 0.8 ml/min and 10 µl** injection volume. After 1.20 min, the mobile phase composition gradually changed to 90% B (acetonitrile) and 10% A (water). Chromatographic separation took 10 min with a 5±0.5 °C auto-sampler temperature. Atmospheric Pressure Chemical Ionization (APCI) in positive ion mode, with clustering potentials of 36–50 V and collision energy of 9–30 eV, was used for quantification. Results: Following International Conference Harmonization (ICHQ2R1), showed regression value more than 0.997 and a signal-to-noise ratio of 3.7-4.5 ppm. Approach achieved Limit of Detection (LOD) values over 3.3-12.7 ppm and Limit of Quantification (LOQ) values over 9.9-36.9 ppm, with signal-to-noise ratios greater than 3.7% and greater than 12.9. All of the method recoveries fell between 80% and 120%. Conclusion: This Liquid Chromatography with Tandem Mass Spectroscopy (LC-MS/MS) technology detects and quantifies nitrosamine impurities in Tamsulosin quickly, sensitively and specifically, assuring regulatory compliance pursuant to USP General chapter<1469>. Impurities in Tamsulosin can be detected at a minimum level using the current technology, which allows for regular analysis.

Authors

Institutions

Publication Details

Journal
International Journal of Applied Pharmaceutics
Published
2025-03-07
DOI
https://doi.org/10.22159/ijap.2025v17i2.52810
Primary Topic
Water Treatment and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DEVELOPMENT AND VALIDATION OF AN LC-MS/MS METHOD FOR NITROSAMINE IMPURITY DETECTION IN TAMSULOSIN HYDROCHLORIDE

Narender Malothu, A. Madhavi, Swetha Sri Remidicherla, Chakravarthi Guntupalli
International Journal of Applied Pharmaceutics
Water Treatment and Disinfection
article

DEVELOPMENT AND VALIDATION OF AN LC-MS/MS METHOD FOR NITROSAMINE IMPURITY DETECTION IN TAMSULOSIN HYDROCHLORIDE

Narender Malothu, A. Madhavi, Swetha Sri Remidicherla, Chakravarthi Guntupalli
article en

Abstract

Objective: Regulatory oversight of pharmaceuticals containing nitrosamine contaminants has intensified in the past few years. Unites States Food and Drug Administration (USFDA), European Medicines Agency (EMA) and other regulatory agencies has been quite proactive in sending out warnings, instructions, and safety messages. This study presents a fast, accurate, and selective way to detect and quantify nitrosamine contaminants in Tamsulosin HCl. Methods: The purification of Tamsulosin using Di Methyl Formamide (DMF) requires monitoring to avoid nitrosamine formation. A 150 × 4.6 mm Symmetry® C18 column (5 µm, 40±1 °C) was used with a mobile phase involving water (98%), acetonitrile (2%) with 0.1% formic acid, where flow velocity was 0.8 ml/min and 10 µl** injection volume. After 1.20 min, the mobile phase composition gradually changed to 90% B (acetonitrile) and 10% A (water). Chromatographic separation took 10 min with a 5±0.5 °C auto-sampler temperature. Atmospheric Pressure Chemical Ionization (APCI) in positive ion mode, with clustering potentials of 36–50 V and collision energy of 9–30 eV, was used for quantification. Results: Following International Conference Harmonization (ICHQ2R1), showed regression value more than 0.997 and a signal-to-noise ratio of 3.7-4.5 ppm. Approach achieved Limit of Detection (LOD) values over 3.3-12.7 ppm and Limit of Quantification (LOQ) values over 9.9-36.9 ppm, with signal-to-noise ratios greater than 3.7% and greater than 12.9. All of the method recoveries fell between 80% and 120%. Conclusion: This Liquid Chromatography with Tandem Mass Spectroscopy (LC-MS/MS) technology detects and quantifies nitrosamine impurities in Tamsulosin quickly, sensitively and specifically, assuring regulatory compliance pursuant to USP General chapter<1469>. Impurities in Tamsulosin can be detected at a minimum level using the current technology, which allows for regular analysis.

International Journal of Applied Pharmaceutics
KES College (CY), Koneru Lakshmaiah Education Foundation (IN)
Openalex Percentile: Top 94%
Water Treatment and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.