Evaluation and comparison of analytical methods for monitoring polymer depolymerization: Application to poly(bisphenol A carbonate) methanolysis

• Controlled methanolysis method for total and partial depolymerization of PBPAC . • A panel of 5 analytical methods adapted to each level of PBPAC degradation. • Comparison of the quantitative and qualitative aspects of these methods. • A novel method to quantify PBPAC depolymerization by FT-IR. • Discussion of the ideal panel of methods based on the LOD and product analysis. Polymer depolymerization after use represents a significant challenge to reduce both the environmental impact of plastic pollution and the utilization of non-sustainable raw materials. Recently, there has been a demand to form a coherent strategy for the analysis of polymer degradation, of which, some approaches have been observed to be used inappropriately or incompletely. This article proposes an analysis strategy for monitoring the depolymerization of poly(bisphenol-A carbonate) (PBPAC), using methanolysis as a model method. It is based on five analytical methods, which our study attempts to combine and compare according to their ideal use case: size exclusion chromatography (SEC), high-performance liquid chromatography (HPLC) and Fourier-transform infrared (FT-IR), nuclear magnetic resonance (NMR) and Matrix Assisted Laser Desorption Ionization − Time of Flight spectroscopy (MALDI-TOF). This strategy allows both a qualitative approach, where the depolymerization products can be identified and a quantitative one, where the percentage of polymer degradation can be determined, together with the detection limit of each associated technique ( i.e. 0.06 %, 20 %, 10 %, 8 % and 0.5 % for SEC, HPLC, FT-IR, NMR and MALDI-TOF respectively). As a result, the range of applications for each analytical method is assessed, and a guide to determine the minimum methods to be used to qualify and quantify degradation is proposed, in relation to the progress of degradation and the yields obtained. This has enabled us to characterize and propose a new quantitative FT-IR-based methodology, compatible with high-throughput screening, to study the degradation of PBPAC, allowing for quantification of degradation from 10 % onwards.

Authors

Institutions

Publication Details

Journal
European Polymer Journal
Published
2025-03-17
DOI
https://doi.org/10.1016/j.eurpolymj.2025.113898
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation and comparison of analytical methods for monitoring polymer depolymerization: Application to poly(bisphenol A carbonate) methanolysis

Vincent Phalip, Egon Heuson, Maryam Momtaz, Sébastien Paul et al.
1 links
European Polymer Journal
Microplastics and Plastic Pollution
article

Evaluation and comparison of analytical methods for monitoring polymer depolymerization: Application to poly(bisphenol A carbonate) methanolysis

Vincent Phalip, Egon Heuson, Maryam Momtaz, Sébastien Paul, Richard M. Martin, Abel Cousin
article en

Abstract

• Controlled methanolysis method for total and partial depolymerization of PBPAC . • A panel of 5 analytical methods adapted to each level of PBPAC degradation. • Comparison of the quantitative and qualitative aspects of these methods. • A novel method to quantify PBPAC depolymerization by FT-IR. • Discussion of the ideal panel of methods based on the LOD and product analysis. Polymer depolymerization after use represents a significant challenge to reduce both the environmental impact of plastic pollution and the utilization of non-sustainable raw materials. Recently, there has been a demand to form a coherent strategy for the analysis of polymer degradation, of which, some approaches have been observed to be used inappropriately or incompletely. This article proposes an analysis strategy for monitoring the depolymerization of poly(bisphenol-A carbonate) (PBPAC), using methanolysis as a model method. It is based on five analytical methods, which our study attempts to combine and compare according to their ideal use case: size exclusion chromatography (SEC), high-performance liquid chromatography (HPLC) and Fourier-transform infrared (FT-IR), nuclear magnetic resonance (NMR) and Matrix Assisted Laser Desorption Ionization − Time of Flight spectroscopy (MALDI-TOF). This strategy allows both a qualitative approach, where the depolymerization products can be identified and a quantitative one, where the percentage of polymer degradation can be determined, together with the detection limit of each associated technique ( i.e. 0.06 %, 20 %, 10 %, 8 % and 0.5 % for SEC, HPLC, FT-IR, NMR and MALDI-TOF respectively). As a result, the range of applications for each analytical method is assessed, and a guide to determine the minimum methods to be used to qualify and quantify degradation is proposed, in relation to the progress of degradation and the yields obtained. This has enabled us to characterize and propose a new quantitative FT-IR-based methodology, compatible with high-throughput screening, to study the degradation of PBPAC, allowing for quantification of degradation from 10 % onwards.

European Polymer JournalVol. 230
Centre National de la Recherche Scientifique (FR), Solvay (Belgium) (BE), Université de Lille (FR), Institut National de Recherche pour l'Agriculture, l'Alimentation et l'Environnement (FR), Unité de catalyse et de chimie du solide de Lille (FR), UMR Transfrontalière BioEcoAgro (FR), Université d'Artois (FR), École Centrale de Lille (FR)
Agence Nationale de la Recherche
Openalex Percentile: Top 96%
Microplastics and Plastic Pollution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.